This study prepared and evaluated polymeric polybutylcyanoacrylate (PBCA) nanoparticles (NPs) that can be used as a new agent for contrast-enhanced intravascular ultrasound (IVUS) imaging with drug delivery capacity. The nanoformulation was successfully developed using suspension polymerisation and characterised in terms of size, size distribution, zeta potential, morphology, stability, toxicity effects, imaging effects and drug release study. The results showed that the nanoparticles were round and hollow, with a particle diameter of 215.8 ± 25.3 nm and a zeta potential of -22.2 ± 4.1 mV. In vitro experiments, the nanoparticles were safe, non-toxic, and stable in nature with the capacity to carry and release drug (ant-miR-126). Moreover, the nanoparticles can match the high-frequency probe of commercially IVUS as a contrast agent to improve the resolution of imaging (the mean echo intensity ratio in the vascular wall increased significantly from 10.89 ± 1.10 at baseline, to 24.51 ± 1.91 during injection and 43.70 ± 0.88 after injection, respectively  < .0001). Overall, a new nano agent with drug-carrying capacity was prepared, which can be used in combination with IVUS for simultaneous diagnosis and targeted therapy of coronary atherosclerosis.

Download full-text PDF

Source
http://dx.doi.org/10.1080/21691401.2024.2334713DOI Listing

Publication Analysis

Top Keywords

agent contrast-enhanced
8
contrast-enhanced intravascular
8
intravascular ultrasound
8
zeta potential
8
nanoparticles
5
imaging
4
ultrasound imaging
4
imaging vitro
4
vitro polybutylcyanoacrylate
4
polybutylcyanoacrylate nanoparticles
4

Similar Publications

The widespread use of gadolinium-based contrast agents for magnetic resonance imaging (MRI) in recent decades has led to a growing demand for Gd and raised environmental concerns due to their direct discharge into wastewater systems. In response, we developed an electrochemical filtration method to recover Gd from patient urine following contrast-enhanced MRI. This method involves modifying a conventional vacuum filtration apparatus by introducing electrodes into the filter membrane, creating a strong electric field of ∼5 kV/m and a steep three-zone pH gradient within the filter membrane.

View Article and Find Full Text PDF

Comparative Diagnostic Performance of Color Doppler Flow Imaging, MicroFlow Imaging and Contrast-enhanced Ultrasound in Solid Renal Tumors.

Acad Radiol

January 2025

Department of Diagnostic and Therapeutic Ultrasonography, Tianjin Medical University Cancer Institute and Hospital, Tianjin, China (C.L., X.W., T.Z., X.W.); National Clinical Research Center for Cancer, Tianjin, China (C.L., L.Q., C.G., H.X., X.W., T.Z., Z.Z., X.W.); Key laboratory of Cancer Prevention and Therapy, Tianjin, China (C.L., L.Q., C.G., H.X., X.W., T.Z., Z.Z., X.W.); Tianjin's Clinical Research Center for Cancer, Tianjin, China (C.L., L.Q., C.G., H.X., X.W., T.Z., Z.Z., X.W.). Electronic address:

Rationale And Objectives: Accurate distinguish malignant from benign renal masses remains a challenge for radiologists. The purpose of this study was to evaluate the value of Color Doppler Flow Imaging (CDFI), MicroFlow Imaging (MFI) and Contrast-enhanced Ultrasound (CEUS) in diagnosing solid renal tumors.

Materials And Methods: A total of 291 patients with 300 solid renal tumors pathologically confirmed were retrospectively analyzed between January 2020 and December 2022.

View Article and Find Full Text PDF

Objectives: Contrast agents are frequently administered in computed tomography (CT) scans used for opportunistic screening of osteoporosis. The objective of this study is to compare the impact of contrast-related bone mineral density (BMD) increase between phantom-based and internal CT calibration techniques.

Materials And Methods: Phantom-based and internal CT calibration techniques were used to determine trabecular BMD in 93 existing clinical CT scans of the lumbar spine of 34 subjects, scanned before and after administration of contrast agents.

View Article and Find Full Text PDF

PEGylated Ultrasmall Iron Oxide Nanoparticles as MRI Contrast Agents for Vascular Imaging and Real-Time Monitoring.

ACS Nano

January 2025

Center for Molecular Imaging and Nuclear Medicine, State Key Laboratory of Radiation Medicine and Protection, School for Radiological and Interdisciplinary Sciences (RAD-X), Soochow University, Collaborative Innovation Center of Radiological Medicine of Jiangsu Higher Education Institutions, Suzhou 215123, China.

Accurate imaging evaluations of pre- and post-treatment of cardiovascular diseases are pivotal for effective clinical interventions and improved patient outcomes. However, current imaging methods lack real-time monitoring capabilities with a high contrast and resolution during treatments. This study introduces PEGylated ultrasmall iron oxide nanoparticles (PUSIONPs), which have undergone comprehensive safety evaluations, boasting an value of 6.

View Article and Find Full Text PDF

A 55-year-old woman with non-small cell lung carcinoma complained of epigastric pain, bloating, anorexia and postprandial nausea and vomiting over a five-year period. An upper gastrointestinal pan-glucosamine contrast examination revealed a distinctive large, hook-shaped, ptotic gastric lumen with normal motility. The contrast agent demonstrated an abnormal round-trip flow anterior to the spine at the duodenal level, with pooling and gradual passage through this region in strands after prolonged retention.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!