Membrane stripping in group B streptococcus carriers does not impede adequate intrapartum antibiotic prophylaxis: a retrospective study.

Front Med (Lausanne)

Department of Obstetrics and Gynecology, Hadassah Hebrew Medical Center and Faculty of Medicine, Hebrew University of Jerusalem, Jerusalem, Israel.

Published: April 2024

Objective: Membrane stripping in group B streptococcus (GBS) carriers poses an increased risk of inadequate antibiotic prophylaxis, potentially due to accelerated labor, thereby potentially impacting the management of GBS colonization during delivery. We compared the adequacy of intrapartum antibiotic prophylaxis between pregnant women colonized with GBS, who underwent membrane stripping and those who did not. The study aimed to determine whether the performance of membrane stripping, by potentially shortening labor duration, increases the risk of inadequate antibiotic prophylaxis dispensation.

Study Design: A retrospective cohort study was conducted on GBS screen-positive women with a full-term singleton pregnancy in cephalic presentation, who were eligible for vaginal delivery. The exposed group consisted of women who underwent membrane stripping, while the unexposed group consisted of women who did not undergo membrane stripping. The primary outcome was defined as inadequate duration of antibiotic prophylaxis during labor, wherein less than 4 h of beta-lactam antibiotics were administered prior to delivery. Neonatal outcome was compared between the groups.

Results: This retrospective cohort study comprised 1,609 women, with 129 in the exposed group (stripping group) and 1,480 in the unexposed group (no stripping group). Adequate intrapartum antibiotic prophylaxis was received by 64.3% (83/129) of the exposed group, compared to 46.9% (694/1,480) of the unexposed group ( = 0.003). Membrane stripping was associated with increased odds of receiving adequate prophylaxis (OR 1.897, 95% CI 1.185-3.037,  = 0.008). After excluding women who presented to the labor ward in active labor and delivered in less than 4 h, both the exposed and unexposed groups had similarly high rates of adequate intrapartum antibiotic prophylaxis (87.5% vs. 85.8%, respectively). No significant difference was observed in adverse neonatal outcomes between the groups.

Conclusion: The provision of membrane stripping did not impede adequate intrapartum antibiotic prophylaxis and was correlated with a higher rate of sufficient prophylaxis in comparison to non-swept patients. These observations suggest that membrane stripping can be considered a safe option for ensuring adequate antibiotic prophylaxis in women colonized with GBS.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11026581PMC
http://dx.doi.org/10.3389/fmed.2024.1368998DOI Listing

Publication Analysis

Top Keywords

membrane stripping
36
antibiotic prophylaxis
36
intrapartum antibiotic
20
stripping group
16
adequate intrapartum
16
exposed group
12
unexposed group
12
prophylaxis
11
group
10
stripping
10

Similar Publications

To evaluate the clinical outcomes of cornea transplantation (penetrating keratoplasty, Descemet membrane endothelial keratoplasty, Descemet stripping automated endothelial keratoplasty, and deep anterior lamellar keratoplasty) using donor corneas stored in Eusol-C hypothermic storage medium compared to corneas stored in organ-culture. : The clinical outcomes of 92 patients who underwent corneal transplantation with human donor corneas stored in Eusol-C medium at 2-8 °C were retrospectively evaluated. The control group consisted of 169 patients who received corneas organ-cultured at 31 °C.

View Article and Find Full Text PDF

This study describes the use of the emulsion liquid membrane (ELM) technique to recover thorium (Th(IV)) from an aqueous nitrate solution. The components of the ELM were kerosene as a diluent, sorbitan monooleate (span 80) as a surfactant, bis(2,4,4-trimethylpentyl)phosphinic acid (Cyanex 272) as an extractant, and HSO solution as a stripping reagent. Th(IV) was more successfully extracted and separated under the following favorable conditions: Cyanex272 concentration of 0.

View Article and Find Full Text PDF

Analysis of time-of-flight secondary ion mass spectrometry data of human skin treated with diclofenac using sparse autoencoder.

Anal Bioanal Chem

December 2024

Faculty of Science and Technology, Seikei University, 3-3-1 Kichijoji-Kitamachi, Musashino, Tokyo, 180-8633, Japan.

Methods that facilitate molecular identification and imaging are required to evaluate drug penetration into tissues. Time-of-flight secondary ion mass spectrometry (ToF-SIMS), which has high spatial resolution and allows 3D distribution imaging of organic materials, is suitable for this purpose. However, the complexity of ToF-SIMS data, which includes nonlinear factors, makes interpretation challenging.

View Article and Find Full Text PDF

The scope of eye banking activities has been expanding with the advances and techniques of keratoplasty. With the popularity of descemet membrane endothelial keratoplasty (DMEK) in the recent decade, there is a need to adopt the preparation of DMEK tissues in the eye banks. This necessitated surgical training of the eye bank technicians, development of infrastructure in the eye bank, innovative methods of graft preparation, and delivery for the surgery at distant surgery centers.

View Article and Find Full Text PDF

Purpose: To identify areas of consensus among experts on the performance of endothelial keratoplasty by using a modified Delphi approach, to help create a framework for novice surgeons to adopt these procedures.

Methods: Thirty-one international experts in endothelial keratoplasty participated. Two rounds of electronic survey were followed by a hybrid, virtual meeting.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!