Introduction Pre-analytical errors in cytology laboratories can significantly impact the accuracy of diagnostic results and turnaround times, ultimately affecting patient care. This article presents an evaluation of pre-analytical errors and proposes fostering strategies to enhance accuracy and efficiency in the cytology laboratory of a tertiary care hospital. The background discusses the importance of pre-analytical processes in ensuring reliable cytological diagnoses and the common errors encountered in specimen collection, handling, and transportation. Strategies for error reduction and improvement in turnaround times include staff education, standardization of procedures, utilization of appropriate collection and transport devices, implementation of quality control measures, and utilization of automation technologies. By addressing pre-analytical errors and implementing fostering strategies, cytology laboratories can optimize diagnostic accuracy, improve patient care outcomes, and enhance overall laboratory efficiency. Aims and objectives This study aims to assess the prevalence and nature of pre-analytical errors in the cytology laboratory of a tertiary care hospital to understand the extent of the issue, identify the specific factors contributing to pre-analytical errors like specimen collection, handling, and transportation processes, and pinpoint areas for improvement. It seeks to evaluate the impact of pre-analytical errors on the accuracy of cytological results and the efficiency of turnaround times, highlighting the consequences for patient care. Furthermore, the study aims to develop targeted strategies to minimize pre-analytical errors and enhance the accuracy of cytological results. Materials and methods This study was conducted at the Cytology Laboratory of our hospital from January 2023 to December 2023 after getting proper approval from the Institutional Review Board (IRB approval number 101/02/2024/PG/SRB/SMCH). It is a retrospective analytical study, and a total of 5412 samples from patients of the outpatient (OP) department, inpatient (IP) department, and community health outreach program facilities received in the cytology laboratory were analyzed during the study period. The inclusion criteria were the test samples sent specifically for cytological analysis. The samples sent for biochemical or microbiological examination were excluded. The frequency of sample distribution and rejected samples were calculated and the results were correlated. Results A total of 5,412 samples received in the cytology laboratory were analyzed during the study period. The majority of the samples were Papanicolaou smears (2,352, 43.5%), followed by fluid cytology (1,008, 18.6%) and ultrasound-guided fine-needle aspiration cytology (FNAC, 984, 18.2%). Of the total number of samples, 225 (4.16%) were repeated and 27 (0.5%) were rejected. Conclusions Pre-analytical, analytical, and post-analytical processes are the three key factors that determine the dependability and precision of cytological test results. Detecting critical alerts such as the positivity of malignancy underscores the paramount importance of result accuracy. Implementing good laboratory practices and conducting both external and internal audits can reduce the frequency of preventable errors in a cytology laboratory, thereby ensuring enhanced precision and expedited outputs.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11031617 | PMC |
http://dx.doi.org/10.7759/cureus.56592 | DOI Listing |
Adv Lab Med
December 2024
Section of Clinical Biochemistry and School of Medicine, University of Verona, Verona, Italy.
Objectives: Urinalysis is widely used and is also frequently requested in emergency situations for screening hypovolemia, urinary tract infections, diabetes, ketoacidosis and hematuria. Our aim was to evaluate the impact of reporting urinary sediment in emergency department specimens with the Sysmex UN system.
Methods: We evaluated urinalyses requested by the emergency department over a three-month period and examined red blood cell count interference, compared leukocyte esterase dipsticks to cytofluorimetric leukocyte count and nitrites to cytofluorimetric bacterial count.
Clin Chem Lab Med
December 2024
Department of Medicine, University Hospital Knappschaftskrankenhaus Bochum GmbH, Ruhr-University Bochum, Bochum, Germany.
Objectives: Diurnal variation of plasma glucose levels may contribute to diagnostic uncertainty. The permissible time interval, (), was proposed as a time-dependent characteristic to specify the time within which glucose levels from two consecutive samples are not biased by the time of blood collection. A major obstacle is the lack of population-specific data that reflect the diurnal course of a measurand.
View Article and Find Full Text PDFHealthcare (Basel)
November 2024
Research Unit of Bioethics and Humanities, Department of Medicine and Surgery, Università Campus Bio-Medico di Roma, 00128 Roma, Italy.
: The frozen section intra-operative consultation is a pathology procedure that provides real-time evaluations of tissue samples during surgery, enabling quick and informed decisions. In the pre-analytical phase, errors related to sample collection, transport, and identification are common, and tools like failure mode, effects, and criticality analysis help identify and prevent risks. This study aims to enhance patient safety and diagnostic quality by analyzing risks and optimizing sample management.
View Article and Find Full Text PDFRev Med Inst Mex Seguro Soc
February 2024
Instituto de Seguridad Social para los Trabajadores del Estado, Hospital Fernando Quiroz Gutiérrez, Servicio de Cardiología. Ciudad de México, México.
Background: Errors in the pre-analytical phase of the microbiology laboratory reduce patient safety and generate additional expenses. In Mexico we do not have systems for evaluation and monitoring of the pre-analytical phase; quality indicators are proposed for continuous improvement.
Objective: Identify the main reasons for rejection of respiratory samples in the microbiology laboratory and evaluate the usefulness of preanalytical quality indicators.
Lab Med
November 2024
Department of Clinical Chemistry, Sestre milosrdnice University Hospital Center, Zagreb, Croatia.
Background And Aims: Preanalytical errors due to interferences can lead to inaccurate results, necessitating an understanding of potential interferences for each test. This study explores the impact of elevated concentrations of ascorbic acid and glucose on urine analysis, a pivotal diagnostic tool.
Methods: Conducted at the Clinical Institute of Chemistry, KBC Sestre milosrdnice, the research utilized a 24-hour urine sample.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!