Background: Haemorrhoids are a common chronic anorectal disease, and haemorrhoidectomy is the standard treatment for advanced (grade III and IV) haemorrhoids. Warm water sitz has commonly been used to stimulate urination, cleanse wounds, and decrease pain. Although urinary retention and pain usually occur within the first 24 h after surgery, the warm water sitz bath is provided 24 h after haemorrhoidectomy, which might be a missed opportunity to optimize the quality and efficiency of the care provided.

Objective: To investigate the effect of early warm water sitz bath on the day of haemorrhoidectomy surgery on preventing urinary retention and reducing wound pain.

Design: This was a longitudinal double-blind study with a permuted block randomization design.

Setting(s): This study was conducted in a surgical ward of a medical center. An average of 18 patients receiving hemorrhoid surgery in that ward every month.

Participants: A total of 64 participants (32 each in the experimental and control groups) were enrolled. (The first recruitment date is January 16, 2020.) METHODS: Patients who received haemorrhoidectomy for grade III or IV haemorrhoids from January to December 2020 were enrolled. The experimental and control groups received the same conventional treatment and care before the haemorrhoidectomy. The experimental group started warm-water sitz bath 6 h after the surgery, and the control group started warm water sitz bath on post-haemorrhoidectomy day 1 as usual. Urinary retention was defined as use of Foley catheter during the hospital stay or remaining urine volume ≧ 300 ml using the bladder scan. A numerical rating scale was used to rate the pain level. Each participant was evaluated 6 times in total until hospital discharge. The data were analysed by descriptive statistics, chi-square test, and independent samples t test. Generalized estimating equations and intention to treat were used to identify changes in urinary retention and pain over time and missing data, respectively.

Results: There was no significant difference in the degree of change in the number of people with urinary retention between groups. A change in the wound pain index was noted; the study group had a statistically significant lower pain score than the control group (B = -0.81, 95 % CI: -1.44 to -0.18).

Conclusions: Early warm water sitz bath was a safe and effective strategy to decrease post-haemorrhoidectomy pain, but not urinary retention. Nurses could provide early warm water sitz bath for post-haemorrhoidectomy patients' comfort.

Registration: ClinicalTrials.gov ID: NCT04535765.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ijnurstu.2024.104765DOI Listing

Publication Analysis

Top Keywords

warm water
28
water sitz
28
sitz bath
28
urinary retention
28
early warm
16
retention pain
12
sitz
8
pain
8
grade iii
8
iii haemorrhoids
8

Similar Publications

Purpose: Postoperative pain is a major concern for patients undergoing ultrasound scalpel-assisted hemorrhoidectomy, potentially exacerbated by delayed wound healing. This study aimed to evaluate the impact of an intimate cleansing gel containing chlorhexidine, hyaluronic acid, and other anti-inflammatory agents (Antroclean Fisioderm) on postoperative pain, itching, and wound healing in patients who had undergone this procedure.

Methods: This multicenter observational case-control study involved a cohort of consecutive adult patients who underwent hemorrhoidectomy using an ultrasound device.

View Article and Find Full Text PDF

A Novel Machine Perfusion System for Enhancing Hepatic Microcirculation Perfusion.

Artif Organs

December 2024

Hubei Provincial Clinical Research Center for Natural Polymer Biological Liver, Hubei Key Laboratory of Medical Technology on Transplantation, National Quality Control Center for Donated Organ Procurement, Transplant Center of Wuhan University, Institute of Hepatobiliary Diseases of Wuhan University, Zhongnan Hospital of Wuhan University, Wuhan, Hubei, China.

Background: Machine perfusion is a promising strategy for safeguarding liver transplants donated after cardiac death (DCD). In this study, we developed and validated a novel machine perfusion approach for mitigating risk factors and salvaging severe DCD livers.

Methods: A novel hypothermic oxygenated perfusion (HOPE) system was developed, incorporating two pumps and an elastic water sac to emulate the functionality of the cardiac cycle.

View Article and Find Full Text PDF

Water-scarce areas are threatened by climate crisis and, thus, there is an urgent need for optimizing water resources management. Remote sensing has been widely used for calculating the evapotranspiration over large areas, which is an essential variable for calculating the actual irrigation needs of crops. The main objective of this work is to design an approach to optimize the irrigation needs for specific crops.

View Article and Find Full Text PDF

Future increase in compound soil drought-heat extremes exacerbated by vegetation greening.

Nat Commun

December 2024

Institute of Carbon Neutrality, Sino-French Institute for Earth System Science, College of Urban and Environmental Sciences, Peking University, Beijing, China.

Compound soil drought and heat extremes are expected to occur more frequently with global warming, causing wide-ranging socio-ecological repercussions. Vegetation modulates air temperature and soil moisture through biophysical processes, thereby influencing the occurrence of such extremes. Global vegetation cover is broadly expected to increase under climate change, but it remains unclear whether vegetation greening will alleviate or aggravate future increases in compound soil drought-heat events.

View Article and Find Full Text PDF

This study focused on analyzing the spatial and vertical distributions of 28 per- and polyfluoroalkyl substances (PFASs), which comprised five precursors and three alternatives, in the water columns of the regional seas surrounding South Korea, such as the Yellow Sea (YS, Y1-Y10), East China Sea (ECS, EC1-EC6), South Sea (SS, S1-S5), and East Sea (ES, E1-E7). The concentrations of these PFASs detected in 204 seawater samples varied from below the limit of detection ( View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!