Fiber-in-tube SPME-CapLC-MS/MS method to determine Aβ peptides in cerebrospinal fluid obtained from Alzheimer's patients.

J Chromatogr A

Departamento de Química da Faculdade de Filosofia, Ciências e Letras de Ribeirão Preto (DQ-FFCLRP), Universidade de São Paulo, Ribeirão Preto, São Paulo, Brazil.

Published: May 2024

Mass spectrometry is characterized by its high sensitivity, ability to measure very low analyte concentrations, specificity to distinguish between closely related compounds, availability to generate high-throughput methods for screening, and high multiplexing capacity. This technique has been used as a platform to analyze fluid biomarkers for Alzheimer's disease. However, more effective sample preparation procedures, preferably antibody-independent, and more automated mass spectrometry platforms with improved sensitivity, chromatographic separation, and high throughput are needed for this purpose. This short communication discusses the development of a fiber-in-tube SPME-CapLC-MS/MS method to determine Aβ peptides in cerebrospinal fluid obtained from Alzheimer's disease patients. To obtain the fiber-in-tube SPME capillary, we longitudinally packed 22 nitinol fibers coated with a zwitterionic polymeric ionic liquid into the same length of the PEEK tube. In addition, this communication compares this fiber-in-tube SPME method with the conventional HPLC scale (HPLC-MS/MS) and when directly coupled to CapESI-MS/MS without chromatographic separation, and, as a case study, discusses the benefits and challenges inherent in miniaturizing the flow scale of the sample preparation technique (fiber-in-tube SPME) to the CapLC-MS/MS system. Fiber-in-tube SPME-CapLC-MS/MS provided LLOQ ranging from 0.09 to 0.10 ng mL, accuracy ranging from 91 to 117 % (recovery), and reproducibility of less than 18 % (RSD). Analysis of the cerebrospinal fluid samples obtained from Alzheimer's disease patients evidenced that the method is robust. At the capillary scale (10 µL min), this innovative method presented higher analytical sensitivity than the conventional HPLC-MS/MS scale. Although fiber-in-tube SPME directly coupled to CapESI-MS/MS offers advantages in terms of high throughput, the sample was dispersed and non-quantitatively desorbed from the capillary at low flow rate. These results highlighted that chromatographic separation is important to decrease the matrix effect and to achieve higher detectability, which is indispensable for bioanalysis.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.chroma.2024.464913DOI Listing

Publication Analysis

Top Keywords

fiber-in-tube spme
16
fiber-in-tube spme-caplc-ms/ms
12
cerebrospinal fluid
12
alzheimer's disease
12
chromatographic separation
12
spme-caplc-ms/ms method
8
method determine
8
determine aβ
8
aβ peptides
8
peptides cerebrospinal
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!