Ischemic preconditioning (IPC) appears to improve exercise performance although there is uncertainty about the intensity dependence of this effect. The present study sought to clarify effects of IPC on physiological responses at and below peak oxygen uptake, including the gas exchange threshold (GET). Ten male and female participants completed five cycling ramp tests (10 W/min) to failure, with the final two tests preceded by either IPC (4 × 5 min 220 mmHg bilateral leg occlusions) or SHAM (20 mmHg), in a randomised crossover design. The rates of O uptake ( O), carbon dioxide output ( CO), and expired ventilation ( ) were measured at rest and throughout exercise. Exercise data were fitted using several functions to identify GET, two ventilatory thresholds and peak O. IPC increased O at GET by ~ 9% (IPC: 1.89 ± 0.51 L/min, SHAM: 1.73 ± 0.56 L/min; p = 0.055) and power output at GET by ~ 11% (IPC: 133 ± 36 W, SHAM: 120 ± 39 W; p = 0.022). In addition, peak power output increased by 2.4% following IPC (IPC: 217 ± 50 W, SHAM: 212 ± 51 W; p = 0.052), but there was no significant effect of IPC on peak O (IPC: 2.87 ± 0.68 L/min, SHAM: 2.84 ± 0.73 L/min; p = 0.60) or the ventilatory thresholds. The present results suggest that IPC improves GET and peak power output but not peak O during a maximal graded test.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11365842 | PMC |
http://dx.doi.org/10.1007/s00421-024-05481-8 | DOI Listing |
J Sports Sci
January 2025
Physical Activity, Sport and Exercise (PHASE) Research Group, School of Allied Health (Exercise Science), Murdoch University, Perth, Australia.
This study examined internal, external training loads, internal:external ratios, and aerobic adaptations for acute and short-term chronic repeated-sprint training (RST) with blood flow restriction (BFR). Using randomised crossover (Experiment A) and between-subject (Experiment B) designs, 15 and 24 semi-professional Australian footballers completed two and nine RST sessions, respectively. Sessions comprised three sets of 5-7 × 5-second sprints and 25 seconds recovery, with continuous BFR (45% arterial occlusion pressure) or without (Non-BFR).
View Article and Find Full Text PDFFront Big Data
January 2025
Climate and Environmental Physics, Physics Institute, University of Bern, Bern, Switzerland.
Atmospheric ozone chemistry involves various substances and reactions, which makes it a complex system. We analyzed data recorded by Switzerland's National Air Pollution Monitoring Network (NABEL) to showcase the capabilities of machine learning (ML) for the prediction of ozone concentrations (daily averages) and to document a general approach that can be followed by anyone facing similar problems. We evaluated various artificial neural networks and compared them to linear as well as non-linear models deduced with ML.
View Article and Find Full Text PDFJ Environ Sci Health A Tox Hazard Subst Environ Eng
January 2025
School of Environmental Engineering, Faculty of Environmental and Safety Engineering, Qingdao University of Science and Technology, Qingdao, China.
Two-chamber microbial fuel cell (MFC) with biogas slurry (BS) of corn stover as the anode substrate and as the cathode substrate was investigated to solve the problem of the accumulation of wastewater generated from biogas plants and to achieve low-cost separation of CO from biogas. A simple two-compartment MFC was constructed using biocatalysis and inexpensive materials without expensive catalysts. The performance of MFC (X1-W, Y1-W, Z1-W) with different biogas solution concentrations as anode substrate and MFC (X2-C, Y2-C, Z2-C) with as biocathode were compared, respectively.
View Article and Find Full Text PDFSci Rep
January 2025
Department of Information Technology, Faculty of Computers and Information, Assiut University, Assiut, Assiut, 71515, Egypt.
Fifth-generation (5G) communication technologies, such as millimeter wave communication, massive multiple-input-multiple-output and non-orthogonal-multiple-access (NOMA) are playing a pivotal role in promoting the modern applications of the Internet-of-Things. Using non-orthogonal resource allocation, NOMA can increase spectrum efficiency and achieve wide connectivity with low transmission delay and signaling cost. Despite the high potential of NOMA in 5G communications, NOMA is susceptible to a pilot contamination attack (PCA), in which an attacker resents the same pilot signals as authorized users.
View Article and Find Full Text PDFSci Rep
January 2025
Faculty of Engineering Sciences Institute of Mechatronics and System Dynamics, University of Duisburg-Essen, 47057, Duisburg, Germany.
Hybrid transmissions have attracted great attention in the automotive industry due to their energy-saving, low-emission properties, and have become a focus of research and development. This paper presents a new method to design the configuration of two mode power split hybrid transmission using the combination of the simple planetary gear trains (PGT). For this purpose, the hybrid transmission structure is divided into two substructures, which achieve different operation modes respectively.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!