Background: Lactational mastitis is a common painful and debilitating inflammation of breast tissue, generally treated conservatively or with pus puncture in case of breast abscess. However, treating mastitis in patients with implantable surgical material located in the affected breast region can be extremely challenging. We present an unusual case of lactational mastitis complicated by pacemaker pocket infection in a breastfeeding mother.
Case Presentation: A 35-year-old pacemaker-dependent female developed lactational mastitis seven weeks postpartum. Initially, the condition was treated conservatively with analgesics and antibiotics. After abscess formation, pus was aspirated using fine-needle aspiration technique. Four weeks after mastitis resolution, pacemaker pocket infection developed. According to current cardiovascular implantable electronic device infection treatment guidelines a complete surgical extraction of the entire electronic system, followed by targeted antibiotic treatment and reimplantation of a new device after infection resolution, was recommended. However, after thorough discussion with the young woman and her family and after detailed review of surgery-related risks, she declined a potentially high-risk surgical procedure. Thus, only the pulse generator was explanted; pacing leads positioned in the sub-pectoral pocket; new pacemaker implanted on the contralateral side and broad-spectrum antibiotic therapy continued for six weeks. After breastfeeding cessation, and with chronic fistula development at the primary pacemaker implantation site, the possibility of delayed surgical intervention including complete extraction of retained pacemaker leads was again thoroughly discussed with her. After thoughtful consideration the woman consented to the proposed treatment strategy. A surgical procedure including transvenous lead extraction through the primary implantation venous entry site, using hand-powered bidirectional rotational sheaths, was successfully performed, removing all retained leads through the left subclavian venous entry site, and leaving the fully functional and clinically uninfected pacemaker on the contralateral site intact.
Conclusion: Although patients' decisions for delayed extraction in a case of cardiovascular implantable electronic device infection should be discouraged by attending physicians and members of interdisciplinary teams, our case shows that a stepwise treatment strategy may be successful as a bailout clinical scenario in patients with specific requests, demands and / or clinical needs.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11027399 | PMC |
http://dx.doi.org/10.1186/s13006-024-00633-0 | DOI Listing |
Front Microbiol
December 2024
Department of Laboratory Medicine, Guangdong Provincial Hospital of Chinese Medicine, Zhuhai, China.
Background: Previous microbiological investigations have demonstrated a significant correlation between complex (CKC) infection and mastitis. Recent studies have confirmed the existence of the CKC, with () identified as the primary infectious agent. Examining the incidence of CKC in cases of severe non-lactational mastitis, alongside the clinical characteristics of infected patients, as well as evaluating the drug sensitivity testing protocols for CKC, can provide a more robust foundation for the diagnosis and treatment of CKC infections.
View Article and Find Full Text PDFJ Adv Nurs
January 2025
School of Nursing, Beijing University of Chinese Medicine, Beijing, China.
Microb Pathog
December 2024
Eastern Regional Station, ICAR-Indian Veterinary Research Institute, Kolkata, 700037, West Bengal, India.
The cure rate of Staphylococcus aureus mastitis by conventional antibiotic therapy is very poor. Diflunisal (DIF), a difluorophenol derivative of salicylic acid, is reported to have strong anti-bacterial and anti-inflammatory effects against S. aureus infection.
View Article and Find Full Text PDFArch Gynecol Obstet
December 2024
Fukushima Regional Center for the Japan Environment and Children's Study, 1 Hikarigaoka, Fukushima, 960-1295, Japan.
Purpose: The association between maternal physique and prevalence of lactational mastitis (LM) in a large study population has not been reported. In this study, we aimed to evaluate the association between pre-pregnancy body mass index (BMI) and LM prevalence.
Methods: We analyzed data collected from participants enrolled in the Japan Environment and Children's Study, a nationwide birth cohort study conducted between 2011 and 2014.
J Dairy Sci
December 2024
Department of Animal Science, Michigan State University, East Lansing, MI 48824.
Body condition score (BCS) and hyperketonemia (HYK) have been associated with diseases, fertility, and culling but data are contradictory about their association with pregnancy loss. Our objective was to conduct a retrospective cohort study to investigate associations between BCS, BCS change (ΔBCS), blood β-hydroxybutyrate (BHB), and HYK with mastitis, pregnancy/artificial insemination (P/AI), pregnancy loss (PGL), milk yield, and risk of leaving the herd on a Michigan dairy farm that uses an automated milking system (AMS). We recorded BCS for cows prepartum (14 d before calving), postpartum (14-21 DIM), and multiparous cows were evaluated for HYK between 3 and 7 DIM.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!