Transcranial magnetic stimulation paired with electroencephalography (TMS-EEG) can measure local excitability and functional connectivity. To address trial-to-trial variability, responses to multiple TMS pulses are recorded to obtain an average TMS evoked potential (TEP). Balancing adequate data acquisition to establish stable TEPs with feasible experimental duration is critical when applying TMS-EEG to clinical populations. Here we aim to investigate the minimum number of pulses (MNP) required to achieve stable TEPs in children with epilepsy. Eighteen children with Self-Limited Epilepsy with Centrotemporal Spikes, a common epilepsy arising from the motor cortices, underwent multiple 100-pulse blocks of TMS to both motor cortices over two days. TMS was applied at 120% of resting motor threshold (rMT) up to a maximum of 100% maximum stimulator output. The average of all 100 pulses was used as a "gold-standard" TEP to which we compared "candidate" TEPs obtained by averaging subsets of pulses. We defined TEP stability as the MNP needed to achieve a concordance correlation coefficient of 80% between the candidate and "gold-standard" TEP. We additionally assessed whether experimental or clinical factors affected TEP stability. Results show that stable TEPs can be derived from fewer than 100 pulses, a number typically used for designing TMS-EEG experiments. The early segment (15-80 ms) of the TEP was less stable than the later segment (80-350 ms). Global mean field amplitude derived from all channels was less stable than local TEP derived from channels overlying the stimulated site. TEP stability did not differ depending on stimulated hemisphere, block order, or antiseizure medication use, but was greater in older children. Stimulation administered with an intensity above the rMT yielded more stable local TEPs. Studies of TMS-EEG in pediatrics have been limited by the complexity of experimental set-up and time course. This study serves as a critical starting point, demonstrating the feasibility of designing efficient TMS-EEG studies that use a relatively small number of pulses to study pediatric epilepsy and potentially other pediatric groups.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11031596PMC
http://dx.doi.org/10.1038/s41598-024-59468-8DOI Listing

Publication Analysis

Top Keywords

tep stability
12
transcranial magnetic
8
magnetic stimulation
8
pediatric epilepsy
8
stable teps
8
number pulses
8
motor cortices
8
100 pulses
8
"gold-standard" tep
8
derived channels
8

Similar Publications

TEP in the ER: After Hours Tracheoesophageal Prosthesis Management for the Otolaryngologist.

Ann Otol Rhinol Laryngol

November 2024

Department of Otolaryngology-Head & Neck Surgery, Winship at Emory Healthcare, Atlanta, GA, USA.

Background: Tracheoesophageal voice puncture and prosthesis (TEP) is a common method of voice restoration following total laryngectomy. A variety of complications, both minor and major, can be associated with the TEP and require timely intervention/management. Some of those complications include premature leakage, periprosthetic leakage, granulation tissue growth, TEP dislodgement, or embedding of the TEP.

View Article and Find Full Text PDF

Ether-Modified Nonflammable Phosphate Enabling Anion-Rich Electrolyte for High-Voltage Lithium Metal Batteries.

Adv Mater

December 2024

Frontiers Science Center for New Organic Matter, Key Laboratory of Advanced Energy Materials Chemistry (Ministry of Education), State Key Laboratory of Advanced Chemical Power Sources, College of Chemistry, Nankai University, Tianjin, 300071, China.

Phosphate-based localized high-concentration electrolytes (LHCE) feature high flame retardant and satisfactory cathodic stability for lithium metal batteries. However, stable cycling of those electrolytes at ultra-high upper cut-off voltages for long-term stability remains challenging. Herein, an ether-modified phosphate, diethyl (2-methoxy ethoxy) methylphosphonate (DMEP), is designed for high-voltage applications.

View Article and Find Full Text PDF

MXene-coated piezoelectric poly-L-lactic acid membrane accelerates wound healing by biomimicking low-voltage electrical pulses.

Int J Biol Macromol

October 2024

Institute of Chemicobiology and Functional Materials, School of Chemistry and Chemical Engineering, Nanjing University of Science and Technology, Nanjing 210094, China. Electronic address:

Electrical stimulation therapy is effective in promoting wound healing by rescuing the decreased endogenous electrical field, where self-powered and miniaturized devices such as nanogenerators become the emerging trends. While high-voltage and unidirectional electric field may pose thermal effect and damage to the skin, nanogenerators with lower voltages, pulsed or bidirectional currents, and less invasive electrodes are preferred. Herein, we construct a polydopamine (PDA)-modified poly-L-lactic acid (PLLA) /MXene (PDMP/MXene) nanofibrous composite membrane that generates piezoelectric voltages matching the transepithelial potential (TEP) to accelerate wound healing.

View Article and Find Full Text PDF

High-Viscosity Phase Inversion Separators for Freestanding and Direct-on-Electrode Manufacturing in Lithium-Ion Batteries.

ACS Appl Mater Interfaces

August 2024

Department of Mechanical Engineering, University of Washington, Seattle, Washington 98195, United States.

Separators play a critical role in lithium-ion batteries (LIBs) by facilitating lithium-ion (Li-ion) transport while enabling safe battery operation. However, commercial separators made from polypropylene (PP) or polyethylene (PE) impose a discrete processing step in current LIB manufacturing as they cannot be manufactured with the same slot-die coating process used to fabricate the electrodes. Moreover, commercial separators cannot accommodate newer manufacturing processes used to produce leading-edge microbatteries and flexible batteries with customized form factors.

View Article and Find Full Text PDF
Article Synopsis
  • The integration of electric vehicles and renewable energy sources into power grids can significantly reduce greenhouse gas emissions and enhance grid stability while promoting green energy use.
  • Current research shows a lack of models addressing transmission expansion planning, demand response, and hosting capacity simultaneously, which could optimize resource use and meet market demands.
  • This study presents a two-layer hosting capacity model that uses advanced optimization techniques to maximize the integration of EVs and RESs, revealing that demand response strategies can effectively lower peak loads without affecting total energy consumption of EVs.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!