Background: The risk of radiation exposure in the surgical operating room (OR) and/or catheterization laboratory is now well established. Complex endovascular procedures often require multiple approaches and different positioning of the staff members around the patient, potentially increasing the levels of radiations exposure. Our goal was to evaluate the levels of radiation exposure of the members of the staff during endovascular aortic procedures in order to propose radioprotection optimization.
Methods: We included 41 aortic endovascular procedures out of 114 procedures performed between January 12, 2014, and August 31, 2015, including 24 standard endovascular aortic aneurysm repair (EVAR), 7 EVAR with iliac branch (EVARib), 8 complex fenestrated/branched EVAR (F/B EVAR), and 2 thoracic EVAR (TEVAR). Procedures were performed in an OR equipped with a carbon fiber table and a mobile fluoroscopy C-arm. We collected the usual dosimetry data given by the C-arm as well as the patient's peak skin dose (PSD). In all staff members, radiation exposure was measured with thermoluminescent chip dosimeters placed on both temples, on posterior sides of both hands, and on both lower legs.
Results: PSD levels were low for EVAR because 24 patients had values below the reading threshold. PSD significantly increased with more complex procedures. Main operator (MO) received the higher level of irradiation on whole body, hands, and ankles. Eye lenses irradiation was higher on both assistant operators (AOs). Other members received low levels of irradiation. We found a high ranges of radiation exposure with a high risk of exposure for the AO, mainly for F/B EVAR and EVARib.
Conclusions: Even if all personal protections are used, staff positioning is a major point that must be considered. If MO is supposed to be the most exposed to X-rays, specific conditions of positioning of the AO may be at risk of exposure.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.avsg.2024.01.004 | DOI Listing |
J Mater Sci Mater Med
January 2025
Department of Nuclear Medicine, Chongqing University Cancer Hospital, No. 181 HanYu St, Shapingba District, Chongqing, 400030, PR China.
Human hair keratin, a natural protein derived from human hair, has emerged prominently in the field of wound repair, showcasing its unique regenerative capabilities and extensive application potential. However, it is a challenge for the keratin to efficiently therapy the impaired wound healing, such as combined radiation-wound injury. Here, we report a keratin/chitosan (KRT/CS) film for skin repair of chronic wounds in in rats with combined radiation-wound injury.
View Article and Find Full Text PDFAstrobiology
January 2025
Experimental Biophysics and Space Sciences, Department of Physics, Freie Universitaet Berlin, Berlin, Germany.
The (PSS) experiment was part of the European Space Agency's mission and was conducted on the International Space Station from 2014 to 2016. The PSS experiment investigated the properties of montmorillonite clay as a protective shield against degradation of organic compounds that were exposed to elevated levels of ultraviolet (UV) radiation in space. Additionally, we examined the potential for montmorillonite to catalyze UV-induced breakdown of the amino acid alanine and its potential to trap the resulting photochemical byproducts within its interlayers.
View Article and Find Full Text PDFBackground: Radiation therapy (RT) treats primary and metastatic brain tumors, with about one million Americans surviving beyond six months post-treatment. However, up to 90% of survivors experience RT-induced cognitive impairment. Emerging evidence links cognitive decline to RT-induced endothelial dysfunction in brain microvessels, yet studies of endothelial injury remain limited.
View Article and Find Full Text PDFDrug Des Devel Ther
January 2025
Department of Hematology, Jining NO. 1 People's Hospital, Jining, 272000, People's Republic of China.
Purpose: Mitoxantrone (MTX) is largely restricted in clinical usage due to its significant cardiotoxicity. Multiple studies have shown that an imbalance in the gut-heart axis plays an important role in the development of cardiovascular disease (CVD). We aim to explore the possible correlations between gut microbiota (GM) compositions and cardiometabolic (CM) disorder in MTX-triggered cardiotoxicity mice.
View Article and Find Full Text PDFInt J Biomed Imaging
January 2025
Medical Imaging Sciences Department, College of Health Sciences, Gulf Medical University, Ajman, UAE.
The quality of CT images obtained from hepatocellular carcinoma (HCC) patients is complex, affecting diagnostic accuracy, precision, and radiation dose assessment due to increased exposure risks. The study evaluated image quality qualitatively and quantitatively by comparing quality levels with an effective radiation dose to ensure acceptable quality accuracy. This study retrospectively reviewed 100 known HCC patients (Li-RADS-5) who underwent multidetector computed tomography (MDCT) multiphasic scans for follow-up of their health condition between January and October 2023.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!