. Digital breast tomosynthesis (DBT) has significantly improved the diagnosis of breast cancer due to its high sensitivity and specificity in detecting breast lesions compared to two-dimensional mammography. However, one of the primary challenges in DBT is the image blur resulting from x-ray source motion, particularly in DBT systems with a source in continuous-motion mode. This motion-induced blur can degrade the spatial resolution of DBT images, potentially affecting the visibility of subtle lesions such as microcalcifications.. We addressed this issue by deriving an analytical in-plane source blur kernel for DBT images based on imaging geometry and proposing a post-processing image deblurring method with a generative diffusion model as an image prior.. We showed that the source blur could be approximated by a shift-invariant kernel over the DBT slice at a given height above the detector, and we validated the accuracy of our blur kernel modeling through simulation. We also demonstrated the ability of the diffusion model to generate realistic DBT images. The proposed deblurring method successfully enhanced spatial resolution when applied to DBT images reconstructed with detector blur and correlated noise modeling.. Our study demonstrated the advantages of modeling the imaging system components such as source motion blur for improving DBT image quality.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11103667 | PMC |
http://dx.doi.org/10.1088/1361-6560/ad40f8 | DOI Listing |
Pharm Res
January 2025
Department of Chemical Engineering, Indian Institute of Technology Delhi, Hauz Khas, New Delhi, 110016, India.
Purpose: Therapeutic monoclonal antibodies (mAbs) are prone to degradation via aggregation and fragmentation. In this study, forced degradation of trastuzumab (TmAb) was explored in saline and in-vitro models having HO and exposed to UV light (case study 1) both bleomycin (BML) formulation and ferrous ions (Fe) (case study 2) and sodium hypochlorite (NaOCl) (case study 3).
Methods: Size exclusion chromatography, dynamic light scattering, spectroscopic analysis, and fluorescence microscope image processing was carried out for characterizing TmAb degradation.
Phys Med
January 2025
Medical Physics Unit, ASST Monza, Monza, Italy.
Purpose: Digital Breast Tomosynthesis (DBT) is an advanced mammography technique for which there are currently no internationally agreed methods and reference values for image quality assessment. The aim of this multicentre study was to evaluate a simple method to assess the technical image quality of reconstructed and synthetic 2D (SM) images of different models of DBT systems using commercially available phantoms.
Methods: The signal difference to noise ratio (SDNR) was chosen as an index of technical image quality and was evaluated for three commercial phantoms, Tomophan, Tormam and CIRS model 015, on 55 DBT systems (six vendors, nine models).
Phys Med
January 2025
National Co-ordinating Centre for the Physics of Mammography (NCCPM), Medical Physics Department, Royal Surrey NHS Foundation Trust, Guildford GU2 7XX UK.
Background: The American Association of Physicists in Medicine (AAPM) Task group 282 (TG282) in collaboration with the European Federation for Organisations of Medical Physics (EFOMP) have developed a novel breast dosimetry model intended as a single international standard.
Purpose: To explore the impact of TG282 dosimetry on estimates of average Mean Glandular Dose (MGD) in the United Kingdom (UK) National Health Service (NHS) Breast Screening Programmes (BSP).
Methods: MGDs were estimated, using the TG282 dosimetry model, for the most recent UK NHSBSP dose survey.
J Med Imaging (Bellingham)
January 2025
Lund University, Department of Translational Medicine, Medical Radiation Physics, Malmö, Sweden.
Purpose: We aim to investigate the characteristics and evaluate the performance of synthetic mammograms (SMs) based on wide-angle digital breast tomosynthesis (DBT) compared with digital mammography (DM).
Approach: Fifty cases with both synthetic and digital mammograms were selected from the Malmö Breast Tomosynthesis Screening Trial. They were categorized into five groups consisting of normal cases and recalled cases with false-positive and true-positive findings from DM and DBT only.
AJR Am J Roentgenol
January 2025
Department of Radiology, Division of Breast Imaging and Intervention, Mayo Clinic, Phoenix, AZ.
Contrast-enhanced mammography (CEM) is growing in clinical use due to its increased sensitivity and specificity compared to full-field digital mammography (FFDM) and/or digital breast tomosynthesis (DBT), particularly in patients with dense breasts. To perform an intraindividual comparison of MGD between FFDM, DBT, a combination protocol using both FFDM and DBT (combined FFDM-DBT), and CEM, in patients undergoing breast cancer screening. This retrospective study included 389 women (median age, 57.