Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Quaternary Ammonium Compounds (QACs) are widely used in household, medical and industrial settings. As a consequence, they are ubiquitously found in the environment. Although significant efforts have been put into the development of sensitive and reproducible analytical methods, much less effort has been dedicated to the monitoring of QACs upon sample storage and sample preparation. Here we studied the effect of storage, concentration, and extraction procedures on the concentrations of QACs in samples. Thirteen QACs selected amongst benzalkonium compounds (BACs), dialkyldimethylammonium compounds (DADMACs) and alkyltrimethylammonium compounds (ATMACs) were quantified in aqueous and solid samples using LC-MS/MS. Most QACs adsorbed on container walls could be recovered using a short washing step with MeOH containing 2 % v/v formic acid. Concentrations of QACs from aqueous solutions using solid phase extraction (SPE) with Strata-X cartridges and elution with acidified MeOH utilized to wash the emptied containers gave highly satisfactory recoveries (101-111 %). Good recoveries (89-116 %) were also obtained when extracting a spiked organic-rich synthetic soil using accelerated solvent extraction (ASE) with acidified MeOH at low solid/solvent ratio (0.4 g/20 mL). Applying the recommended methodologies to real samples collected from a Canadian wastewater treatment plant (WWTP) gave QAC concentrations in the ranges of 0.01-30 µg/L, < 1.2 µg/L, and 0.05-27 mg/kg for the influent, effluent and biosolids samples, respectively.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.chroma.2024.464905 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!