Department of Epidemiology, Erasmus MC University Medical Center, Rotterdam, the Netherlands; Department of Radiology and Nuclear Medicine, Erasmus MC University Medical Center, Rotterdam, the Netherlands; Department of Epidemiology, Harvard T.H. Chan School of Public Health, Boston, Massachusetts, USA. Electronic address:

Published: September 2024

Rationale: The pulmonary artery (PA) diameter-to-aorta ratio (PA:A) ratio is a novel marker in cardiovascular imaging for detecting pulmonary hypertension. However, we question the effect of the varying aorta diameter on the ratio, which complicates the interpretation of the PA:A ratio.

Objective: Investigate the variability of the PA:A ratio by examining the correlation between PA:A ratio and aorta diameter and by comparing the associations of the PA diameter, aorta diameters, and PA:A ratio.

Methods: We included 2197 participants from the Rotterdam Study who underwent non-contrast multidetector computed tomography to measure the PA and aorta diameters. Pearson correlation coefficient was calculated between the PA:A ratio and aorta diameter. Multiple linear regression analyses were performed to compare the determinants of the individual diameters and PA:A ratio.

Results: We found a statistically significant correlation between the PA:A ratio and aorta diameter (r = -0.38, p < 0.001). The PA diameter was statistically significantly associated with, height, weight, diastolic blood pressure, blood pressure medication, prevalence of atrial fibrillation, prevalence of heart failure, and prevalence of stroke (p < 0.05). Except for blood pressure medication, the PA:A ratio had similar determinants compared to the PA diameter but was also statistically significantly associated with sex, and systolic blood pressure (p < 0.05), which were statistically significantly associated with the aorta diameter (p < 0.05).

Conclusion: The PA:A ratio should not be interpreted without taking into account the variability of the individual components (PA and aorta diameter) according to the anthropomorphic and clinical characteristics.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.acra.2024.03.037DOI Listing

Publication Analysis

Top Keywords

paa ratio
20
aorta diameter
16
ratio aorta
12
rotterdam study
8
paa
8
correlation paa
8
aorta diameters
8
diameters paa
8
ratio
7
aorta
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!