Modern radiotherapy techniques have advanced and become more sophisticated. End-to-end 3D verification of the complex radiotherapy dose distribution in an anthropomorphic phantom can ensure the accuracy of the treatment delivery. The phantoms commonly used for dosimetry are homogeneous solid water phantom which lacks the capability to measure the 3D dose distribution for heterogeneous tissues necessary for advanced radiotherapy techniques. Therefore, we developed an end-to-end 3D radiotherapy dose verification system based on MAX-HD anthropomorphic phantom (Integrated Medical Technologies Inc., Troy, New York) with bespoke intracranial insert for PRESAGE® dosimeter. In this study, several advanced radiotherapy treatment techniques of various levels of complexity; 3D-CRT, IMRT and VMAT treatment, were planned for a 20 mm diameter of a spherical target in the brain region and delivered to the phantom. The dosimeters were read out using an in-house developed optical computed tomography (OCT) imaging system known as 3DmicroHD-OCT. It was found that the measured dose distribution of the PRESAGE® when compared with the measured dose distribution of EBT film and Monaco TPS has a maximum difference of less than 3% for 3D-CRT, IMRT and VMAT treatment plans. The gamma analysis results of PRESAGE® in comparison to EBT film and Monaco TPS show pass rates of more than 95% for the criteria of 3% dose difference and 3 mm distance-to-agreement. This study proves the capability of PRESAGE® and bespoke MAX-HD phantom in conjunction with the 3DmicroHD-OCT system to measure 3D dose distribution for end-to-end dosimetry verification.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s13246-024-01418-9 | DOI Listing |
Allergol Int
December 2024
Department of Allergy, Clinical Research Center for Allergy and Rheumatology, NHO Sagamihara National Hospital, Kanagawa, Japan. Electronic address:
Background: Low-dose (LD) oral food challenge (OFC) with heated cow's milk (CM; 3 mL) effectively prevents CM elimination in children with CM allergy (CMA). We investigated the long-term prognoses after an LD-OFC for CMA.
Methods: Children with immediate CMA symptoms after consuming <25 mL of CM within 2 years of a baseline LD-OFC were retrospectively analyzed.
Anticancer Res
January 2025
Proton Medical Research Center, University of Tsukuba, Ibaraki, Japan.
Background/aim: This study aimed to predict the optimal timing for adaptive radiation therapy (ART) using two-dimensional X-ray image-based water equivalent thickness (2DWET).
Patients And Methods: Forty patients with oropharyngeal and hypopharyngeal cancer underwent Computed Tomography (CT) rescanning during treatment. An adaptive score (AS) was proposed to guide ART decisions based on changes in four dose indices: target coverage, spinal cord dose, parotid gland dose, and over-dose volume.
Clin Oncol (R Coll Radiol)
December 2024
Alberta Health Services, South Zone, Lethbridge, AB, Canada; University of Calgary, Department of Oncology, Calgary, AB, Canada; University of Calgary, Department of Physics and Astronomy, Calgary, AB, Canada.
Aims: Prostrate-specific membrane antigen positron emission tomography (PSMA-PET) imaging has led to an increase in identifiable small volume metastatic disease in prostate adenocarcinoma. There is clinical equipoise in how to treat these using radiotherapy regimens. The aim of this study is to determine an adequate dosing regimen for small volume lymphatic metastases in prostate adenocarcinoma.
View Article and Find Full Text PDFJ Med Imaging Radiat Sci
December 2024
Department of Radiotherapy, Instituto Brasileiro de Controle do Câncer (IBCC), Avenida Alcântara Machado, 2576, Mooca, 03102-002 São Paulo, SP, Brazil; Department of Radiotherapy, Instituto de Radiologia do Hospital das Clínicas - HCFMUSP (InRad), Hospital das Clínicas, University of São Paulo, Rua Doutor Ovídio Pires de Campos, 75, Portaria 1, Cerqueira César, 05403-010 São Paulo, SP, Brazil.
Purpose: Radiotherapy is a crucial part of breast cancer treatment. Precision in dose assessment is essential to minimize side effects. Traditionally, anatomical structures are delineated manually, a time-consuming process subject to variability.
View Article and Find Full Text PDFClin Nutr
December 2024
Key Laboratory for Disease Prevention and Control and Health Promotion of Shaanxi Province, Department of Epidemiology and Biostatistics, School of Public Health, Global Health Institute, Xi'an Jiaotong University Health Science Center, 710061, Xi'an, Shaanxi, China; Key Laboratory of Environment and Genes Related to Diseases of Ministry of Education of China, Xi'an Jiaotong University, 710061, Xi'an, Shaanxi, China. Electronic address:
Background & Aims: Obesity directly contributes to the progression of cardiovascular disease, but little is known about the association and risk attribution of normal-weight obesity subtypes with the incidence of major vascular events (MVEs) and their subtypes.
Methods: This is a prospective cohort study based on the China Kadoorie Biobank (CKB). A total of 308,071 individuals with no prior vascular diseases or cancer were included at baseline.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!