A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Comparing three cardiothoracic ratio measurement techniques and creating multivariable scoring system to predict Bart's hydrops fetalis at 17-22 weeks' gestation. | LitMetric

To assess the diagnostic performance of three cardiothoracic (CT) ratio techniques, including diameter, circumference, and area, for predicting hemoglobin (Hb) Bart's disease between 17 and 22 weeks' gestation, and to create a multivariable scoring system using multiple ultrasound markers. Before invasive testing, three CT ratio techniques and other ultrasound markers were obtained in 151 singleton pregnancies at risk of Hb Bart's disease. CT diameter ratio demonstrated the highest sensitivity among the other techniques. Significant predictors included CT diameter ratio > 0.5, middle cerebral artery-peak systolic velocity (MCA-PSV) > 1.5 multiples of the median, and placental thickness > 3 cm. MCA-PSV exhibited the highest sensitivity (97.8%) in predicting affected fetuses. A multivariable scoring achieved excellent sensitivity (100%) and specificity (84.9%) for disease prediction. CT diameter ratio exhibited slightly outperforming the other techniques. Increased MCA-PSV was the most valuable ultrasound marker. Multivariable scoring surpassed single-parameter analysis in predictive capabilities.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11024143PMC
http://dx.doi.org/10.1038/s41598-024-59719-8DOI Listing

Publication Analysis

Top Keywords

multivariable scoring
16
three cardiothoracic
8
cardiothoracic ratio
8
scoring system
8
ratio techniques
8
bart's disease
8
ultrasound markers
8
diameter ratio
8
highest sensitivity
8
ratio
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!