Background: Steps have been taken by pharmaceutical companies to obtain marketing authorisation of PSMA ligands in the European Union. Since December 2022, Locametz® (PSMA-11, gozetotide) is licensed as kit for manual radiolabelling with gallium-68 and commercially available since mid-2023. The Summary of Product Characteristic (SmPC) describes manual radiolabelling with a maximum activity after radiolabelling of 1369 MBq. We aimed for radiolabelling with a higher activity to increase production efficiency, and thus, automated radiolabelling is strongly preferred over manual radiolabelling to reduce radiation exposure to personnel. The aim of this study was to develop and validate a method for automated radiolabelling of the Locametz® kit using ~ 2000 MBq of gallium-68 eluate for radiolabelling.

Results: Automated radiolabelling of [Ga]Ga-PSMA-11 using the Locametz® kit provided a product which complies to the Ph. Eur., had a shelf-life of 6 h at room temperature, and theoretically reduced radiation exposure 5.7 times. Radiolabelling with one and two generator(s) resulted in a radiochemical yield of 91-102% and 96-101% after preparation, respectively. The radiochemical purity ranged from 98.0 to 99.6% for radiolabelling with one generator and ranged from 98.4 to 99.3% for radiolabelling with two generators with similar stability. The activity of the final product was much higher when using two generators, 1961-2035 MBq compared to 740-1260 MBq, which leads to ~ 1.5 times more patient syringes available per preparation.

Conclusion: Automated radiolabelling of [Ga]Ga-PSMA-11 using the Locametz® kit with higher gallium-68 activity than specified in the SmPC results in a product that is in compliance with the Ph. Eur. monograph and has a shelf-life of 6 h at room temperature. Radiolabelling with two generators proved possible and resulted in a product with similar quality but with much higher efficiency.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11024066PMC
http://dx.doi.org/10.1186/s41181-024-00260-4DOI Listing

Publication Analysis

Top Keywords

automated radiolabelling
20
locametz® kit
16
radiolabelling
13
radiolabelling [ga]ga-psma-11
12
manual radiolabelling
12
radiolabelling generators
12
radiation exposure
8
[ga]ga-psma-11 locametz®
8
shelf-life 6 h
8
6 h room
8

Similar Publications

Time-efficient HPLC Validation Methodology for the Qualitative Analysis of 68Ga PSMA-11 in Routine Clinical Usage under Isocratic Method.

Indian J Nucl Med

November 2024

Department of Nuclear Medicine and Molecular Imaging, Homi Bhabha Cancer Hospital and Mahamana Pandit Madan Mohan Malaviya Cancer Centre, Tata Memorial Centre, Homi Bhabha National Institute, Varanasi, Uttar Pradesh, India.

Background: Prostate-specific membrane antigen (PSMA) has shown to be a promising agent for prostate cancer imaging under PET-CT. With the automation in radiolabeling with 68Ga, using iTG 68Ge/68Ga generator, it has helped introduce various new diagnostic agents and achieve good manufacturing practices (GMP) simultaneously. However, before any radiopharmaceutical is put into clinical usage, it should always be checked for its radiochemical purity and other quality parameters before injecting in the patient.

View Article and Find Full Text PDF

A successful positron emission tomography imaging program involving carbon-11 radiotracers demands fast, efficient, and reliable synthesis methods, requiring an on-site cyclotron and radiochemistry group, as well as clinical staff trained to operate under the unique constraints of the carbon-11 radionuclide. This study examines the merits and advantages of a captive solvent 'loop method' of radiolabeling four tracers with the carbon-11 radionuclide, producing the radioligands [C]ER-176, [C]MRB, [C]mHED, and [C]PiB. The 'loop method' is compared against the traditional reactor-based method of carbon-11 methylation in the course of synthesizing the same radiotracers on the identical automated platform.

View Article and Find Full Text PDF

Purpose: Radiolabelled minigastrin (MG) analogues targeting the cholecystokinin-2 receptor (CCK2R) have proven to be a promising approach for peptide receptor radionuclide therapy (PRRT). In this study, we report on the radiopharmaceutical development and standardization of the preparation of [Lu]Lu-DOTA-MGS5 using an automated synthesis module. Furthermore, we present the preclinical tests required to move forward towards a first therapeutic clinical trial as well as preliminary clinical dosimetry data.

View Article and Find Full Text PDF

Lead-it-EAZY! GMP-compliant production of [Pb]Pb-PSC-PEG-TOC.

EJNMMI Radiopharm Chem

November 2024

Department of Nuclear Medicine, University Hospital Carl Gustav Carus, Technical University Dresden, Fetscherstr. 74, 01307, Dresden, Germany.

Background: Recently, radiotheranostics comprising the true matched radionuclide pair Pb could serve as real dosimetric planning utility using Pb-radiolabelled pharmaceuticals before therapy with Pb-radiolabelled counterparts. Pb might act as the missing radionuclide therapy between standard β therapies (e.g.

View Article and Find Full Text PDF

In nuclear medicine, molecular imaging of the tumor microenvironment using radiopharmaceuticals (RPs) targeting cancer-associated fibroblasts is gaining significant interest. Among these RPs, [Ga]Ga-FAPI-46 for positron emission tomography (PET) imaging is frequently used in clinical research protocols. To ensure that the production of this RP complies with good manufacturing practices, process automation is widely adopted.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!