Background: Sinus node dysfunction (SND) is commonly seen in patients with atrial fibrillation (AF). The purpose of this study was to compare the incidence of pacemaker implantation among patients with SND and AF treated with catheter ablation (CA) versus anti-arrhythmic drugs (AADs).

Methods: The 2013-2022 Optum Clinformatics database, an administrative claims database for commercially insured individuals in the United States (US), was used for this study. Patients with AF and SND and a history of at least one AAD prescription were identified and classified into CA or AAD cohorts based on subsequent treatment received. Inverse probability treatment weighting was applied to balance socio-demographic and clinical characteristics between the cohorts. Weighted Cox regression modeling was used to evaluate the differential risk of incident permanent pacemaker (PPM) implantation. Sub-analyses were performed by AF type (paroxysmal versus persistent).

Results: A total of 1206 patients in the AAD cohort and 1624 patients in the CA cohort were included. Study cohorts were well-balanced post-weighting. The incidence rate of PPM implantation (per 1000 person-year) was 55.8 for the CA cohort and 117.8 for the AAD cohort. Regression analysis demonstrated that the CA cohort had 42% lower risk of incident PPM implantation than those treated with AADs (hazard ratio [HR], 0.58; 95% CI, 0.46-0.72, p < 0.001). CA-treated patients had lower risks of PPM implantation versus AAD-treated patients among those with paroxysmal AF (HR, 0.48; 95% CI, 0.34-0.69, p < 0.001) and persistent AF (HR, 0.57; 95% CI, 0.40-0.81, p = 0.002).

Conclusions: Patients with AF and SND treated with CA have significantly lower risks of incident PPM implantation compared with those treated with an AAD.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11522185PMC
http://dx.doi.org/10.1007/s10840-024-01790-2DOI Listing

Publication Analysis

Top Keywords

ppm implantation
12
incidence pacemaker
8
pacemaker implantation
8
implantation patients
8
patients atrial
8
atrial fibrillation
8
sinus node
8
node dysfunction
8
ablation versus
8
patients snd
8

Similar Publications

Introduction: Conductive disturbances requiring permanent pacemaker (PPM) implantation remain a major concern after transcatheter aortic valve implantation (TAVI).

Aims: To assess the impact of aortic valve calcium score (AVCS) on conductive disturbances requiring PPM after TAVI.

Methods: All patients who underwent TAVI with accessible AVCS from the preprocedural CT scan report were included in this retrospective single-centre study.

View Article and Find Full Text PDF

Background: Evidence regarding the incidence of prosthesis-patient mismatch (PPM) and long-term mortality after transcatheter aortic valve replacement (TAVR) in patients with bicuspid aortic valve stenosis (AS) is scarce.

Objectives: This study sought to assess the incidence and prognostic impact of PPM after TAVR for bicuspid AS compared with that for tricuspid AS.

Methods: In total, 7,393 patients who underwent TAVR were prospectively enrolled in the OCEAN-TAVI (Optimized Catheter Valvular Intervention Transcatheter Aortic Valve Implantation) registry, an ongoing Japanese, multicenter registry.

View Article and Find Full Text PDF
Article Synopsis
  • The study focused on creating and testing Cobalt-doped zinc oxide nanoparticles as a photocatalyst for degrading the antibiotic ciprofloxacin (CIPF) under visible LED light.
  • It was found that 10% Cobalt-doped ZnO nanoparticles were the most effective, achieving over 99% degradation of CIPF in just 90 minutes, and maintained their efficiency across three cycles of use.
  • The research also optimized the conditions for maximum degradation efficiency using statistical methods and simulated data using Artificial Neural Networks, achieving a strong correlation for the model’s accuracy.
View Article and Find Full Text PDF

Permanent pacemaker (PPM) implantation is the standard of care in patients with complete heart block (CHB) and second-degree type II atrioventricular (AV) block irrespective of patient symptoms when the conduction abnormality is irreversible. CHB generally constitutes a medical emergency that can be fatal if not urgently treated. This is in contrast to first-degree AV block and second-degree type I AV block, which require PPM implantation only in very special circumstances.

View Article and Find Full Text PDF

When should the tricuspid valve be repaired during mitral valve repair?

Curr Opin Cardiol

December 2024

Division of Cardiac Surgery, Department of Surgery, Western University, London, Ontario, Canada.

Purpose Of Review: Management of tricuspid regurgitation and annular dilation during mitral valve repair remains controversial. We review the latest evidence on indications to repair the tricuspid valve during mitral valve repair and discuss surgical strategies and complications.

Recent Findings: Concomitant tricuspid valve repair of moderate tricuspid regurgitation is effective in reducing tricuspid regurgitation progression at 2 years, but has not shown benefit to late survival, quality of life, or functional benefit, and is associated with increased permanent pacemaker implantation (PPM) rates, which is associated with reduced late survival.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!