Objective: To compare the effectiveness of three surgical methods in the treatment of Pauwels type Ⅲ femoral neck fracture in young and middle-aged patients, in order to provide reference for clinical selection of appropriate surgical methods.

Methods: The clinical data of 103 patients with Pauwels type Ⅲ femoral neck fracture who met the selection criteria between June 2018 and December 2021 were retrospectively analyzed. The fractures were fixed with hollow screws in an inverted triangular shape (37 cases, hollow screw group), hollow screws in an inverted triangular shape combined with eccentric shaft screw (34 cases, eccentric shaft screw group), and hollow screws in an inverted triangular shape combined with medial support plate (32 cases, support plate group). There was no significant difference in age, gender, cause of injury, body mass index, time from injury to operation, side of the fracture, and Garden classification, whether they were in traction preoperatively, and other baseline data between groups ( >0.05). The operation time, intraoperative blood loss, the number of fluoroscopy, the length of hospital stay, early postoperative complication and postoperative weight-bearing time of the three groups were recorded. Harris score was used to evaluate joint function at 6 and 12 months after operation, and the difference between the two time points (change value) was calculated for comparison between groups. X-ray films were reviewed to evaluate the quality of fracture reduction (Garden index) and healing, as well as the occurrence of internal fixation failure and femoral head necrosis.

Results: The patients of the three groups were successfully completed. Compared with the hollow screw group and the eccentric shaft screw group, the operation time and intraoperative blood loss of the support plate group significantly increased, the number of fluoroscopy reduced, and the quality of fracture reduction was better, the differences were significant ( <0.05). The operation time, intraoperative blood loss, and the number of fluoroscopy of the hollow screw group were less than those of the eccentric shaft screw group, the differences were significant ( <0.05). There was no significant difference in the length of hospital stay between groups ( >0.05). All patients in the three groups were followed up 21-52 months, with an average follow-up time of 36.0 months, and there was no significant difference between groups ( >0.05). The incisions of all patients healed by first intention. Imaging reexamination showed that there was no significant difference in the incidence of fracture nonunion between groups ( >0.05). The fracture healing, partial weight-bearing, and full weight-bearing were significantly earlier in the eccentric shaft screw group and the support plate group than in the hollow screw group ( <0.05). There was no significant difference in change value of Harris score, the incidence of postoperative deep venous thrombosis and femoral head necrosis between groups ( >0.05); however, the incidence of internal fixation failure in the support plate group and the eccentric shaft screw group was significantly lower than that in the hollow screw group ( <0.05). The incidence of postoperative lateral thigh irritation in the support plate group was significantly lower than that in the hollow screw group ( <0.05); there was no significant difference between the eccentric shaft screw group and the other two groups ( >0.05). The overall incidences of postoperative complications in the eccentric shaft screw group and the support plate group were significantly lower than that in the hollow screw group ( <0.05).

Conclusion: For young and middle-aged patients with Pauwels type Ⅲ femoral neck fracture, compared with simple hollow screw fixation in an inverted triangular shape, combined with medial support plate or eccentric shaft screw internal fixation can shorten the fracture healing time, reduce the incidences of postoperative complication, more conducive to early functional exercise of the affected limb; at the same time, the operation time and blood loss of combined eccentric shaft screw internal fixation are less than those of combined medial support plate internal fixation, so the hollow screw in an inverted triangular shape combined with eccentric shaft screw fixation may be a better choice.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11024523PMC
http://dx.doi.org/10.7507/1002-1892.202401110DOI Listing

Publication Analysis

Top Keywords

screw group
32
eccentric shaft
20
shaft screw
20
support plate
20
hollow screw
16
plate group
16
pauwels type
12
femoral neck
12
neck fracture
12
hollow screws
12

Similar Publications

Purpose: The fixation method commonly employed worldwide for treating unstable fractures of the posterior pelvic ring is the percutaneous iliosacral screw technique. However, prolonged operation time and frequent fluoroscopies result in surgical risks. This study aimed to investigate whether a new triangulation method could reduce operative and fluoroscopy times and increase the accuracy of screw placement.

View Article and Find Full Text PDF

The study aimed to evaluate a newly designed semicircular implant for the fixation of Vancouver Type B1 periprosthetic femoral fractures (PFFs) in total hip arthroplasty (THA) patients. To determine its strength and clinical applicability, the new implant was compared biomechanically with conventional fixation methods, such as lateral locking plate fixation and a plate combined with cerclage wires. : Fifteen synthetic femur models were used in this biomechanical study.

View Article and Find Full Text PDF

Valgus-impacted femoral neck fractures (OTA 31B1.1 and 31B1.2) are considered stable fractures with favorable outcomes compared to displaced fractures.

View Article and Find Full Text PDF

Introduction: We propose and assess the biomechanical stability of medial column screw supplementation in a synthetic distal femur fracture model.

Materials And Methods: Twenty-four low density synthetic femora modeling osteoporotic, intraarticular distal femur fractures with medial metaphyseal comminution were split into two fixation groups: (1) lateral locking distal femur plate (PA- plate alone) and (2) lateral locking distal femur plate with a 6.5 mm fully threaded medial cannulated screw (PWS- plate with screw).

View Article and Find Full Text PDF

Background: Fixation of distal femoral fractures remains a challenge, and nonunions are common with standard constructs. Far cortical locking (FCL) constructs have been purported to lead to improved fracture-healing as compared with that achieved with traditional locking bridge plates. We sought to test this hypothesis in a comparative effectiveness clinical trial.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!