Statement Of Problem: Three-dimensional (3D) printing of cobalt chromium (Co-Cr) removable partial dentures (RPDs)by selective laser melting (SLM) has been claimed to be less challenging than by conventional casting and provides significant improvements. However, the adaptation and fit of the SLM framework and the optimum build orientation are still unclear.
Purpose: The purpose of this in vitro and clinical study was to evaluate the effect of different build orientations on the adaptation of removable partial denture frameworks fabricated by SLM technology in vitro and to compare the adaptation of the SLM and conventional RPD frameworks clinically.
Material And Methods: A master model simulating a maxillary arch of Kennedy class III modification 1 was scanned and duplicated to create a virtual 3D cast and reference cast. Four groups (n=40) of Co-Cr RPD frameworks were fabricated. For the SLM groups, the Co-Cr framework was virtually designed and exported for SLM printing. The SLM printing was done in 3 different build orientations: 0-degree (n=10), 45-degree (n=10), and 90-degree (n=10) groups. Other Co-Cr frameworks were conventionally cast (n=10). All Co-Cr frameworks were scanned and virtually superimposed with the master model using a surface-matching software program. The gap under 9 selected points in the palatal major connectors was analyzed and calculated. A smaller gap indicates more surface adaptation and close contact between the palatal major connector and the master model. The data were analyzed using the Kruskal-Wallis and Dunnett T3 tests (α=.05). Three patients with a partially dentate maxillary arch were enrolled in the clinical part based on inclusion criteria. Two RPD frameworks were provided for each patient (conventional casting and SLM printing). The adaptation of each framework was assessed by measuring the gap between the palatal major connector of the framework and the palate with light-body silicone. The differences in adaptation between the conventional and SLM frameworks were compared by using independent t tests (α=.05).
Results: The in vitro study identified significant differences in the adaptation of the palatal major connector among the 4 groups (P<.001), except for conventional and 0-degree SLM printing (P=.999). The conventional and 0-degree SLM frameworks exhibited the best adaptation, with the lowest gap underneath the palatal major connector of the RPD framework (0.01 ±0.02 mm and 0.01 ±0.01 mm, respectively). In the clinical part of the study, no significant difference was found between the adaptation of SLM and the conventional framework (P=.430) CONCLUSIONS: The adaptation of SLM printing can be maximized with less gap under the palatal major connector of the RPD framework when using the 0-degree build orientation. Co-Cr frameworks produced with SLM printing technology were comparable with conventionally produced frameworks; hence, SLM printed frameworks can be an alternative for clinical applications when optimum SLM parameters are applied.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.prosdent.2024.03.020 | DOI Listing |
Dental Press J Orthod
January 2025
Federal University of Minas Gerais, School of Dentistry, Department of Restorative Dentistry (Belo Horizonte/MG, Brazil).
Objective: To evaluate the quality of YouTube™ and TikTok™ videos as educational tools for patients with cleft lip and palate (CLP) as regards their care, and multidisciplinary treatment.
Methods: Videos were searched on YouTube™ and TikTok™ using four keywords. The reliability and quality of the first 60 videos for each keyword and platform were analyzed.
J Small Anim Pract
January 2025
Langford Veterinary Services, Langford, UK.
Objectives: To report the clinical presentation, treatment and outcomes of four cats diagnosed with Menrath ulcers causing significant oral haemorrhage.
Materials And Methods: For all cats, data on signalment, history, physical examination, treatment and outcomes were collected by reviewing medical records. Information regarding outcomes was collected from communication logs between primary care veterinarians and owners, and the original case clinicians after discharge of the patient from the hospital.
Ear Nose Throat J
January 2025
Department of Otolaryngology-Head & Neck Surgery, Lehigh Valley Health Network, Allentown, PA, USA.
Kaposi's sarcoma (KS) is a tumor involving blood vessels and lymphatic tissue. It is caused by human herpes virus-8, typically in HIV infection in individuals with AIDS. There are 4 major types of KS including classic, endemic, immunosuppression, and AIDS-related.
View Article and Find Full Text PDFJ Indian Soc Periodontol
December 2024
Department of Periodontology and Implantology, G. Pulla Reddy Dental College and Hospital, Kurnool, Andhra Pradesh, India.
Background: The present study aims to evaluate a three-dimensional (3D) changes in the crestal bone levels (buccally, lingually/palatally, mesially, and distally) and in the thickness of keratinized tissue around single or multiple implants using cone-beam computed tomography (CBCT) after 1 year.
Materials And Methods: Twenty-eight implants were placed in the posterior load-bearing areas in 10 patients. The crestal bone levels and the thickness of keratinized tissue surrounding the edentulous area were assessed preoperatively, immediately after implant placement, and 1 year after implant placement using CBCT (3D imaging technique with DICOM software (Carestream Health, Rochester, NY)).
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!