A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Clinical feasibility of post-contrast accelerated 3D T1-Sampling Perfection with Application-optimized Contrasts using different flip angle Evolutions (SPACE) with iterative denoising for intracranial enhancing lesions: a retrospective study. | LitMetric

Background: Post-contrast T1-Sampling Perfection with Application-optimized Contrasts using different flip angle Evolutions (SPACE) is the preferred 3D T1 spin-echo sequence for evaluating brain metastases, regardless of the prolonged scan time.

Purpose: To evaluate the application of accelerated post-contrast T1-SPACE with iterative denoising (ID) for intracranial enhancing lesions in oncologic patients.

Material And Methods: For evaluation of intracranial lesions, 108 patients underwent standard and accelerated T1-SPACE during the same imaging session. Two neuroradiologists evaluated the overall image quality, artifacts, degree of enhancement, mean contrast-to-noise ratio, and number of enhancing lesions for standard and accelerated T1-SPACE without ID.

Results: Although there was a significant difference in the overall image quality and mean contrast-to-noise ratio between standard and accelerated T1-SPACE without ID and accelerated SPACE with and without ID, there was no significant difference between standard and accelerated T1-SPACE with ID. Accelerated T1-SPACE showed more artifacts than standard T1-SPACE; however, accelerated T1-SPACE with ID showed significantly fewer artifacts than accelerated T1-SPACE without ID. Accelerated T1-SPACE without ID showed a significantly lower number of enhancing lesions than standard- and accelerated T1-SPACE with ID; however, there was no significant difference between standard and accelerated T1-SPACE with ID, regardless of lesion size.

Conclusion: Although accelerated T1-SPACE markedly decreased the scan time, it showed lower overall image quality and lesion detectability than the standard T1-SPACE. Application of ID to accelerated T1-SPACE resulted in comparable overall image quality and detection of enhancing lesions in brain parenchyma as standard T1-SPACE. Accelerated T1-SPACE with ID may be a promising replacement for standard T1-SPACE.

Download full-text PDF

Source
http://dx.doi.org/10.1177/02841851241245104DOI Listing

Publication Analysis

Top Keywords

accelerated t1-space
52
enhancing lesions
20
standard accelerated
20
t1-space accelerated
20
t1-space
18
accelerated
16
image quality
16
standard t1-space
16
standard
9
t1-sampling perfection
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!