On the Use of the Fricke-Pluronic F-127 Gel Dosimeter for Radiation Isocenter Testing of a Medical Linear Accelerator.

Materials (Basel)

Department of Mechanical Engineering, Informatics and Chemistry of Polymer Materials, Faculty of Materials Technologies and Textile Design, Lodz University of Technology, 90-543 Lodz, Poland.

Published: March 2024

This work presents a Fricke-XO-Pluronic F-127 2D radiochromic dosimeter with a flat-bed scanner for 2D reading and a dedicated data processing software package as a tool for performing coincidence testing of the radiation and mechanical isocenter of a medical accelerator. The optimal irradiation parameters were determined as follows: monitor units per beam and multi-leaf collimator gap, which are ≤750-≤2500 MU and 2-5 mm, respectively, for a cuboidal container with dimensions of 12 × 12 × 0.3 cm. Despite the diffusion of Fe ions occurring during irradiation, 2D reading can be performed at least 3 h after irradiation, without affecting the calculation performance of the coincidence test. The test was successfully performed for various irradiation settings. Overall, the Fricke-XO-Pluronic F-127 dosimeter has proven to be a potential tool for the coincidence testing of medical accelerators.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11012804PMC
http://dx.doi.org/10.3390/ma17071521DOI Listing

Publication Analysis

Top Keywords

testing medical
8
fricke-xo-pluronic f-127
8
coincidence testing
8
performed irradiation
8
fricke-pluronic f-127
4
f-127 gel
4
gel dosimeter
4
dosimeter radiation
4
radiation isocenter
4
isocenter testing
4

Similar Publications

TiO-Based Implantable Memristor for Biomedical Engineering.

ACS Appl Mater Interfaces

January 2025

Frontier Institute of Science and Technology (FIST), Xi'an Jiaotong University, Xi'an, Shaanxi 710049, China.

Implantable memristors are considered an emerging electronic technology that can simulate brain memory function and demonstrate some promising applications in the biomedical field. However, it remains a critical challenge to enhance their long-term stability and biocompatibility in implantation environments. In this work, an implantable memristor has been successfully fabricated based on TiO using magnetron sputtering.

View Article and Find Full Text PDF

Study Objective: We use national emergency department (ED) data to identify the proportion of "telehealth-able" ED visits, defined as potentially conductible by Video Only or Video Plus (with limited outpatient testing).

Methods: We used ED visits by patients 4 years of age and older from the 2019 National Hospital Ambulatory Medical Care Survey and applied survey weighting for national representativeness. Two raters categorized patient-described Reasons for Visit (RFV) as telehealth-able (yes, no, uncertain) for both Video Only and Video Plus visits.

View Article and Find Full Text PDF

Objective: Assess if a virtual culinary medicine program improves healthy eating, glycosylated hemoglobin (HbA1c), and associated variables among adults with type 2 diabetes.

Design: Mixed-methods, intervention-only pilot study.

Setting: Classes via video conferencing from the teaching kitchen, with participants cooking from their homes.

View Article and Find Full Text PDF

Self-Collected Testing for Sexually Transmitted Infections: A National Text Message Survey of Adolescents and Young Adults.

J Adolesc Health

January 2025

University of Michigan Department of Obstetrics and Gynecology, Ann Arbor, Michigan; Institute for Healthcare Policy and Innovation, University of Michigan, Ann Arbor, Michigan; Department of Health Behavior and Health Equity, University of Michigan School of Public Health, Ann Arbor, Michigan. Electronic address:

Purpose: We aimed to analyze adolescent and young adults' (AYAs) perspectives on using sexually transmitted infection (STI) self-collection kits to help guide the provision and implementation of accessible and confidential reproductive health-care services for those who experience the burden of STIs and STI-related morbidity.

Methods: We utilized MyVoice, a nationwide text message survey of AYAs, to pose 6 open-ended questions on their perceptions and use of STI self-collection kits. Two independent reviewers used inductive content analysis to develop a codebook and analyze responses, and a third settled any coding discrepancies through discussion to reach consensus.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!