Energy-resolved mass spectrometry (ERMS) and an isotopically labelled internal standard were successfully combined to accurately quantify a tryptic peptide despite the presence of an isobaric interference. For this purpose, electrospray ionisation tandem mass spectrometry (ESI-MS/MS) experiments were conducted into an ion trap instrument using an unconventional 8 m/z broadband isolation window, which encompassed both the tryptic peptide and its internal standard. Interference removal was assessed by determining an excitation voltage that was high enough to maintain a constant value for the analyte/internal standard peaks intensity ratio, thus ensuring accurate quantification even in the presence of isobaric contamination. Pseudo-multiple reaction monitoring (MRM) was employed above this excitation voltage to quantify the trypic peptide. The internal standard calibration model showed no lack of fit and exhibited a linear dynamic range from 0.5 μM up to 2.5 μM. The detection limit was 0.08 μM. The accuracy of the method was evaluated by quantifying the tryptic peptide of three reference samples intentionally contaminated with the isobaric interference. All the reference samples were accurately quantified with ∼1% deviation despite the isobaric contamination. Furthermore, we have demonstrated that this methodology can also be applied to quantify the isobaric peptide by standard additions down to 0.2 μM. Finally, liquid chromatography ERMS (LC ERMS) experiments yielded similar results, suggesting the potential of the proposed methodology for analysing complex samples.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jms.5025DOI Listing

Publication Analysis

Top Keywords

tryptic peptide
16
isobaric interference
12
mass spectrometry
12
internal standard
12
pseudo-multiple reaction
8
reaction monitoring
8
energy-resolved mass
8
presence isobaric
8
peptide internal
8
excitation voltage
8

Similar Publications

Reversed-phase liquid chromatography (RPLC) is an essential tool for separating complex mixtures such as proteolytic digests in bottom-up proteomics. There is growing interest in methods that can predict the RPLC retention behavior of peptides and other analytes. Already, existing algorithms provide excellent performance based on empirical rules or large sets of RPLC training data.

View Article and Find Full Text PDF

Background: Commonly, ligand-binding platforms are being used for immunogenicity assessment, but with the recent advent of liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) for protein quantification, this technology has become an alternative for the measurement of anti-drug antibodies (ADAs), when combined with an immunocapture step to extract them out of the biological sample.

Method: The monoclonal antibody adalimumab was immobilized on magnetic beads to isolate ADAs against this drug from serum samples. Multiple repetitions of immunopurification were used to minimize nonspecific binding and improve drug tolerance while maintaining sufficient recovery.

View Article and Find Full Text PDF

The identification of small proteins and proteins produced from unannotated open reading frames (called alternative proteins or AltProts) has changed our vision of the proteome and has attracted more and more attention from the scientific community. Despite several studies investigating particular AltProts in diseases and demonstrating their importance in such context, we are still missing data on their expression and functions in many pathologies. Among these, pancreatic ductal adenocarcinoma (PDAC) is a particularly relevant case to study alternative proteins.

View Article and Find Full Text PDF

In mass spectrometry-based proteomics, loss-minimized peptide purification techniques play a key role in improving sensitivity and coverage. We have developed a desalting tip column packed with thermoplastic polymer-coated chromatographic particles, named ChocoTip, to achieve high recoveries in peptide purification by pipet-tip-based LC with centrifugation (tipLC). ChocoTip identified more than twice as many peptides from 20 ng of tryptic peptides from Hela cell lysate compared to a typical StageTip packed with chromatographic particles entangled in a Teflon mesh in tipLC.

View Article and Find Full Text PDF

Here we show that when using a mix of 274 light synthetic peptide standards (NAT) as surrogates for 270 human plasma proteins, as well as stable isotope-labelled standards (SIS) as normalizers (both from MRM Proteomics Inc.) for targeted quantitative analysis by liquid chromatography multiple reaction monitoring mass spectrometry (LC/MRM-MS), the Seer Proteograph™ platform allowed for the enrichment and absolute quantitation of up to an additional 62 targets (median) compared to two standard proteomic workflows without enrichment, representing an increase of 44%. The nanoparticle-based fractionation workflow resulted in improved reproducibility compared to a traditional proteomic workflow with no fractionation (median 8.

View Article and Find Full Text PDF