Statement Of Problem: Maxillary and mandibular scans can be articulated in maximum intercuspal position (MIP) by using an artificial intelligence (AI) based program; however, the accuracy of the AI-based program locating the MIP relationship is unknown.

Purpose: The purpose of the present clinical study was to assess the accuracy of the MIP relationship located by using 4 intraoral scanners (IOSs) and an AI-based program.

Material And Methods: Conventional casts of a participant mounted on an articulator in MIP were digitized (T710). Four groups were created based on the IOS used to record a maxillary and mandibular scan of the participant: TRIOS4, iTero, i700, and PrimeScan. Each pair of nonarticulated scans were duplicated 20 times. Three subgroups were created: IOS, AI-articulated, and AI-IOS-corrected subgroups (n=10). In the IOS-subgroup, 10 duplicated scans were articulated in MIP by using a bilateral occlusal record. In the AI-articulated subgroup, the remaining 10 duplicated scans were articulated in MIP by using an AI-based program (BiteFinder). In the AI-IOS-corrected subgroup, the same AI-based program was used to correct the occlusal collisions of the articulated specimens obtained in the IOS-subgroup. A reverse engineering program (Geomagic Wrap) was used to calculate 36 interlandmark measurements on the digitized articulated casts (control) and each articulated specimen. Two-way ANOVA and pairwise multiple comparison Tukey tests were used to analyze trueness (α=.05). The Levene and pairwise multiple comparison Wilcoxon rank tests were used to analyze precision (α=.05).

Results: Significant trueness discrepancies among the groups (P<.001) and subgroups (P<.001) were found, with a significant interaction group×subgroup (P<.001). The Levene test showed significant precision discrepancies among the groups (P<.001) and subgroups (P=.005). The TRIOS4 and iTero groups obtained better trueness and lower precision than the i700 and PrimeScan systems. Additionally, the AI-articulated subgroup showed worse trueness and precision than the IOS and AI-IOS-corrected subgroups. The AI-based program improved the MIP trueness of the scans articulated by using the iTero and PrimeScan systems but reduced the MIP trueness of the articulated scans obtained by using the TRIOS4 and i700.

Conclusions: The trueness and precision of the maxillomandibular relationship was impacted by the IOS system and program used to locate the MIP.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.prosdent.2024.03.007DOI Listing

Publication Analysis

Top Keywords

scans articulated
12
ai-based program
12
maximum intercuspal
8
intercuspal position
8
located intraoral
8
intraoral scanners
8
maxillary mandibular
8
mip relationship
8
duplicated scans
8
articulated mip
8

Similar Publications

Statement Of Problem: Intraoral scans can be articulated in maximum intercuspal position (MIP) by using an artificial intelligence (AI) based program; however, the impact of edentulous areas on the accuracy of the MIP located using this AI-based program is unknown.

Purpose: The purpose of this in vitro study was to assess the impact of edentulous areas (0, 1, 2, 3, and 4 posterior mandibular teeth) on the accuracy of the MIP located using 3 intraoral scanners (IOSs) and an AI-based program.

Material And Methods: Stone casts articulated in MIP in an articulator were digitized (T710).

View Article and Find Full Text PDF

Treatment of posterolateral tibial plateau fractures through the articular line approach.

BMC Musculoskelet Disord

January 2025

Department of Orthopedics, Lishui Central Hospital, Zhejiang, 323000, China.

Background: Posterolateral tibial plateau fractures pose significant challenges for orthopedic surgeons due to the anatomical risks associated with the posterolateral approach. Despite numerous surgical techniques available, there lacks a consensus on the optimal approach.

Methods: Articular line incision approach was employed on 12 patients suffering from posterolateral tibial plateau fractures.

View Article and Find Full Text PDF

Purpose: The degenerative joint disease is a temporomandibular disorder. By analysing texture parameters, it becomes possible to characterize and differentiate various tissues, based on their textural properties according to cone-beam computed tomography (CBCT). This study evaluated degenerative diseases in the temporomandibular joint through texture analysis.

View Article and Find Full Text PDF

Background: Early knee effusion is a common phenomenon after total knee arthroplasty (TKA), with potential clinical implications. Unlike traditional alloy knee prostheses, the polyetheretherketone (PEEK) knee system has radiographic transparency on magnetic resonance (MR) scans, which allows analysis of prosthetic knee effusion. We aimed to identify the distribution and volume of knee effusion after TKA with the PEEK prosthesis with use of MR imaging and to analyze whether dynamic changes in effusion were correlated with serum inflammatory marker changes and knee function recovery.

View Article and Find Full Text PDF

Optimizing hip MRI: enhancing image quality and elevating inter-observer consistency using deep learning-powered reconstruction.

BMC Med Imaging

January 2025

Department of Magnetic Resonance Imaging, The First Affiliated Hospital, Zhengzhou University, Zhengzhou, 450052, China.

Background: Conventional hip joint MRI scans necessitate lengthy scan durations, posing challenges for patient comfort and clinical efficiency. Previously, accelerated imaging techniques were constrained by a trade-off between noise and resolution. Leveraging deep learning-based reconstruction (DLR) holds the potential to mitigate scan time without compromising image quality.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!