Droplets on inclined substrates can depin and slide freely above a critical substrate inclination angle. Pinning can be caused by topographical defects on the substrate, and understanding the influence of defect geometry on the pinning-depinning transition is important for diverse applications such as fog harvesting, droplet-based microfluidic devices, self-cleaning surfaces, and inkjet printing. Here, we develop a lubrication-theory-based model to investigate the motion of droplets on inclined substrates with a single three-dimensional Gaussian-shaped defect that can be in the form of a bump or a dent. A precursor-film/disjoining-pressure approach is used to capture contact-line motion, and a nonlinear evolution equation is derived which describes droplet thickness as a function of the position along the substrate and time. The evolution equation is solved numerically using an alternating direction implicit finite-difference scheme to study how the defect geometry influences the critical inclination angle and the shape of a pinned droplet. It is found that the critical substrate inclination angle increases as the defect becomes taller/deeper or wider along the direction lateral to the droplet-sliding direction. However, the critical inclination angle decreases as the defect becomes wider along the sliding direction. Below the critical inclination angle, the advancing contact line of the droplet at the droplet centerline is pinned to the defect at the point having maximum negative slope. Simple scaling relations that reflect the influence of defect geometry on the droplet retention force arising from surface tension are able to account for many of the trends observed in the numerical simulations.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1039/d4sm00081a | DOI Listing |
Biomed Phys Eng Express
January 2025
Children's Hospital of Eastern Switzerland, Claudiusstrasse 6, St.Gallen, 9006, SWITZERLAND.
Mapping the myomagnetic field of a straight and easily accessible muscle after electrical stimulation using triaxial optically pumped magnetometers (OPMs) to assess potential benefits for magnetomyography (MMG). Approach: Six triaxial OPMs were arranged in two rows with three sensors each along the abductor digiti minimi (ADM) muscle. The upper row of sensors was inclined by 45° with respect to the lower row and all sensors were aligned closely to the skin surface without direct contact.
View Article and Find Full Text PDFCatheter Cardiovasc Interv
January 2025
Department of Cardiac Surgery, Nanjing Drum Tower Hospital, Nanjing Drum Tower Hospital Clinical College of Nanjing Medical University, Nanjing, Jiangsu, China.
Background And Objectives: Currently, there remains a paucity of research on the deformation and valve function of transcatheter heart valves (THV) in patients with aortic regurgitation (AR) following transcatheter aortic valve replacement (TAVR). This study aimed to thoroughly explore the correlation between THV deformation and postoperative hemodynamics in these patients.
Methods: In this study, we assessed 39 AR patients treated with the J-Valve THV system during TAVR.
Hip Int
January 2025
Department of Orthopaedic Surgery, The Ottawa Hospital, Ottawa, Ontario, Canada.
Background: Different methods can help to optimise sagittal cup orientation in total hip arthroplasty (THA) based on individual spinopelvic characteristics. This study aimed to: (1) assess how often combined sagittal index (CSI) and hip-spine-classification targets were achieved post THA; (2) compare anteversion/inclination between cups in-/outside optimal CSI zone; and (3) determine association with outcome.
Methods: This is a multicentre, prospective, case-cohort study of 435 primary THA for osteoarthritis (53% females; age: 65 ± 12 years; follow-up: 2.
J Clin Med
January 2025
Shoulder and Elbow Surgery, Schulthess Clinic Zürich, 8008 Zürich, Switzerland.
: Classical reverse shoulder arthroplasty (RSA) with a high neck-shaft angle (NSA) of 155° has shown satisfactory outcomes. However, newer RSA designs aim to improve results by modifying the stem design. This study evaluates the 5-year outcomes of a stem design featuring a rectangular metadiaphyseal fixation and a 135° NSA.
View Article and Find Full Text PDFJ Clin Med
January 2025
Department of Orthopedics and Traumatology, Private Medicabil Hospital, 16140 Nilüfer/Bursa, Türkiye.
: Developmental dysplasia of the hip (DDH), defined by the malalignment of the femoral head and acetabulum, is a major precursor to coxarthrosis, posing substantial challenges during total hip arthroplasty (THA). Patients with coxarthrosis secondary to DDH often exhibit acetabular bone insufficiency, which makes challenging surgical reconstruction difficult. This study aimed to compare the radiologic and functional outcomes of robotically assisted and conventional manual THA techniques in patients with coxarthrosis secondary to Crowe type III-IV DDH.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!