  • This study evaluated the short-term outcomes of a Chinese-made trabecular titanium acetabular cup (3D ACT™) in total hip replacement surgery, focusing on clinical and imaging results.
  • 236 patients who received this implant showed significant improvements in hip function and pain relief over an average follow-up of 42 months, with most expressing satisfaction.
  • The cup had a 100% survival rate and maintained proper positioning, suggesting promising initial stability and effectiveness, though further research is needed for long-term validation.

Article Abstract

Purpose: We prospectively evaluate the short-term clinical and radiographic outcomes of the only Chinese domestically produced trabecular titanium acetabular cup(3D ACT™ cup) in primary total hip arthroplasty (THA), aiming to provide evidence-based support for its clinical application.

Methods: A total of 236 patients, who underwent primary THA using 3D ACT™ cup in the Department of Joint Surgery at our hospital between January 2017 and June 2019, were included in this study. General patient data, imaging information, functional scores, and complications were collected to evaluate the early clinical efficacy.

Results: All patients were followed up for 33-52 months, with an average of (42.2 ± 9.2) months. At the last follow-up, the preoperative HHS score increased significantly from 43.7 ± 6.8 to 85.6 ± 9.3 points ( < 0.01). Similarly, the preoperative WOMAC scores showed significant improvement from 59.2 ± 5.8 to 13.1 ± 3.5 points ( < 0.01). 92.3% of the patients expressed satisfaction or high satisfaction with the clinical outcome. Furthermore, 87.7% of the acetabular cups were positioned within the Lewinnek safe zone, achieving successful reconstruction of the acetabular rotation center. The cup survival rate at the last follow-up was 100%.

Conclusions: The utilization of the only Chinese domestically manufactured 3D printing trabecular titanium acetabular cup in primary THA demonstrated favorable short-term clinical and radiographic outcomes. The acetabular cup exhibits excellent initial stability, high survival rate, and favorable osseointegration, leading to a significant enhancement in pain relief and functional improvement. In the future, larger sample sizes and multicenter prospective randomized controlled trials will be required to validate the long-term safety and effectiveness of this 3D ACT™ cup.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11004300PMC
http://dx.doi.org/10.3389/fsurg.2024.1279194DOI Listing

Publication Analysis

Top Keywords

short-term clinical
8
clinical radiographic
8
radiographic outcomes
8
outcomes chinese
8
chinese domestically
8
trabecular titanium
8
titanium acetabular
8
cup primary
8
primary total
8
total hip
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!