A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Femoral interference screw divergence as a result of anteromedial portal insertion and outside-in FlipCutter femoral tunnel drilling: A cadaveric study. | LitMetric

Aims And Objectives: To investigate whether interference screw fixation through an anteromedial portal into an outside-in drilled femoral tunnel via a flip cutter results in acceptable hardware position.

Materials & Methods: 10 cadaveric knees underwent ACL-reconstruction with patellar BTB autograft. Femoral tunnel drilling was performed utilizing an outside-in flip cutter drill and interference screws for femoral fixation. Lateral and anterior-posterior (AP) fluoroscopic images were taken to measure screw divergence within the femoral tunnel. The means of AP and lateral divergence angles were compared using two-tailed t-tests.

Results: Using the flip cutter, the AP and lateral divergence angles were 7.3° ± 4.5° and 9.3° ± 9.3°, respectively, while the total divergence angles were 16.6° ± 11.8°. Divergence angles using a cannulated reamer were found to be 14.4° ± 2.5° and 6.8° ± 2.8° for AP and lateral, respectively and 21.1° ± 5.2° for the total divergence. The AP divergence angles using the flip cutter were significantly less than those reported using a cannulated reamer (p = 0.001).

Conclusions: The flip cutter method resulted in significantly reduced divergence angle between the screw and graft when compared to previous cadaveric studies in the coronal plane. There was no significant difference in divergence angle in the sagittal plane. Both methods appear to result in divergence angles below the threshold which would be considered to significantly decrease pull-out strength. Large standard deviations also reflect limited sample size but may also suggest more variability in divergence when compared to historical control set. This study clearly establishes the outside-in technique using a retrograde reamer as a viable independent femoral drilling solution for ACL reconstruction when using a BTB autograft with a femoral interference screw.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11001622PMC
http://dx.doi.org/10.1016/j.jor.2024.03.035DOI Listing

Publication Analysis

Top Keywords

divergence angles
24
flip cutter
20
femoral tunnel
16
interference screw
12
divergence
12
femoral
8
femoral interference
8
screw divergence
8
anteromedial portal
8
tunnel drilling
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!