Attitudes towards healthcare in the NHS and in other Western healthcare systems have been changing dramatically in recent years. There is a significant movement calling for a shift from the traditional paternalistic model, with patients as passive recipients of treatments that are supported by objective and observable evidence, towards a more holistic approach, in which patients have agency, and treatments are tailored to the individual needs of a particular patient. Whilst patient safety and clinical effectiveness remain intrinsic to the traditional measurement of successful healthcare, Patient Reported Outcome Measures (PROMs) are increasingly being advocated as an important tool to uphold patient-centric care in the NHS.The aim of this study is to complete the first evaluation of PROMs that we know of in patients receiving surgical management of zygomatic fractures, by comparing two interventions commonly used in this condition: the zygomaticomaxillary complex open reduction and internal fixation (ZMC ORIF), and the Gillies approach to zygomatic elevation. We demonstrate high levels of patient satisfaction across all domains, irrespective of surgical approach, but that mood and anxiety remain an issue after surgery.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.bjoms.2024.02.001 | DOI Listing |
Drug Alcohol Depend
January 2025
RAND, Boston, MA, United States. Electronic address:
Importance: States have implemented multiple policies likely to influence opioid prescribing; few national general population studies examine those policies' effects on per-capita opioid morphine milligram equivalents (MME) dispensed.
Objective: To examine state policies' effects on opioids per-capita MMEs dispensed at retail pharmacies.
Design: A longitudinal study of associations between MME per capita and implementation of policy interventions at different times across states.
Comput Med Imaging Graph
January 2025
CAS Key Laboratory of Molecular Imaging, Institute of Automation, Chinese Academy of Sciences, Beijing 100190, China; School of Artificial Intelligence, University of Chinese Academy of Sciences, Beijing 100049, China; National Key Laboratory of Kidney Diseases, Beijing 100853, China. Electronic address:
In clinical optical molecular imaging, the need for real-time high frame rates and low excitation doses to ensure patient safety inherently increases susceptibility to detection noise. Faced with the challenge of image degradation caused by severe noise, image denoising is essential for mitigating the trade-off between acquisition cost and image quality. However, prevailing deep learning methods exhibit uncontrollable and suboptimal performance with limited interpretability, primarily due to neglecting underlying physical model and frequency information.
View Article and Find Full Text PDFEur J Radiol
January 2025
Department of Diagnostic and Interventional Radiology, Medical Center-University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany; Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, USA. Electronic address:
Purpose: To evaluate the feasibility of aortoiliac CT-Angiography (CTA) using dual-source photon-counting detector (PCD)-CT with minimal iodine dose.
Methods: This IRB-approved, single-center prospective study enrolled patients with indications for aortoiliac CTA from December 2022 to March 2023. All scans were performed using a first-generation dual-source PCD-CT.
Eur J Radiol
January 2025
Department of Radiology and Nuclear Medicine, University Medical Center Mannheim, Heidelberg University, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim, Germany. Electronic address:
Objectives: Coronary CT angiography (CCTA) is an excellent tool in ruling out coronary artery disease (CAD) but tends to overestimate especially highly calcified plaques. To reduce diagnostic invasive catheter angiographies (ICA), current guidelines recommend CT-FFR to determine the hemodynamic significance of coronary artery stenosis. Photon-Counting Detector CT (PCCT) revolutionized CCTA and may improve CT-FFR analysis in guiding patients.
View Article and Find Full Text PDFEur J Radiol
January 2025
Third Hospital of Shanxi Medical University, Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Tongji Shanxi Hospital, Taiyuan, 030032, China; Department of Pulmonary and Critical Care Medicine, Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Third Hospital of Shanxi Medical University, Tongji Shanxi Hospital, Taiyuan, 030032, China; Department of Pulmonary and Critical Care Medicine, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, China. Electronic address:
Purpose: This head-to-head comparative meta-analysis aimed to evaluate the comparative diagnostic efficacy of [F]FDG PET/CT and dynamic contrast-enhanced CT(DCE-CT) for the differentiation between malignant and benign pulmonary nodules.
Methods: An extensive search was conducted in the PubMed, Embase, and Web of Science to identify available publications up to March 23, 2024. Studies were included if they evaluated the diagnostic efficacy of [F]FDG PET/CT and DCE-CT for the characterization of pulmonary nodules.