A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Evaluation of the 3D Technology in the Auto-transplantation: An Original Research. | LitMetric

Evaluation of the 3D Technology in the Auto-transplantation: An Original Research.

J Pharm Bioallied Sci

Department of Oral and Maxillofacial Surgery, Narsinhbhai Patel Dental College and Hospital, Sankalchand Patel University, Visnagar, Gujarat, India.

Published: February 2024

Introduction: Using three-dimensional printed duplicates of the donor teeth, three-dimensional auto-transplantation is a medical procedure that moves a tooth from one location inside a patient to another. The intraoperative practicability during 3D auto-transplantation of teeth was evaluated in the present study.

Material And Methods: A prospective multicenter clinical study was done among the subjects. and were used in all operations to make a 3D duplicate of the donor teeth. The clinical parameters that were evaluated were the time required for the fit, number of attempts to fit, and intra-operative experience.

Results: Canines, premolars, molars, and one extra tooth were all transplanted during the 200 auto-transplantation surgeries among 152 subjects. An initial satisfactory fit of the donor tooth and an extra-alveolar time of less than one minute were achieved in 80% of the surgeries. The extra-alveolar time exceeded 3 minutes in ten teeth. Difficulties that were faced were related to the imaging, patient cooperation, and the bone quality.

Conclusions: The application of the duplicate teeth by 3D printing of a donor tooth all through auto-transplantation techniques reduced the time the tooth stays extra-alveolar as well as the efforts at transplant fitting during implantation. This allowed for more challenging surgeries as well as a speedy and reliable therapy.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11001007PMC
http://dx.doi.org/10.4103/jpbs.jpbs_429_23DOI Listing

Publication Analysis

Top Keywords

donor teeth
8
donor tooth
8
extra-alveolar time
8
auto-transplantation
5
teeth
5
tooth
5
evaluation technology
4
technology auto-transplantation
4
auto-transplantation original
4
original introduction
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!