Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: The polysomnography (PSG) is the gold-standard for obstructive sleep apnea (OSA) syndrome diagnosis and assessment under positive airway pressure (PAP) therapies in children. Recently, an innovative digital medicine solution, including a mandibular jaw movement (MJM) sensor coupled with automated analysis, has been validated as an alternative to PSG for pediatric application.
Objective: This study aimed to assess the reliability of MJM automated analysis for the assessment of residual apnea/hypopnea events during sleep in children with OSA treated with noninvasive ventilation (NIV) or continuous PAP (CPAP).
Methods: In this open-label prospective non-randomized multicentric trial, we included children aged from 5 to 18 years with a diagnosis of severe OSA. The children underwent in-laboratory PSG with simultaneous MJM monitoring and at-home recording with MJM monitoring 3 months later. Agreement between PSG and MJM analysis in measuring the residual apnea-hypopnea index (AHI) was evaluated by the Bland-Altman method. The treatment effect on residual AHI was estimated for both PSG and MJM analysis.
Results: Fifteen (60% males) children were included with a median age of 12 years [interquartile range 8-15]. Two (17%) were ventilated with NIV and 13 (83%) with CPAP. There was a good agreement between MJM-AHI and PSG-AHI with a median bias of -0.25 (95% CI: -3.40 to +2.04) events/h. The reduction in AHI under treatment was consistently significant across the three measurement methods: in-laboratory PSG and MJM recordings in the laboratory and at home.
Conclusion: Automated analysis of MJM is a highly reliable alternative method to assess residual events in a small population treated with PAP therapies.