This paper presents an investigation on the forming characteristics of the tailor rolled blank of an aluminum alloy (Al-TRB) during three-point bending at room temperature through experiments and finite element simulations. The strain distribution, spring-back characteristics, and metal flow law of 6000 series Al-TRB during three-point bending are explored. The prepared Al-TRB has good bending properties, and no surface cracks appear in the bending region of the Al-TRB when bent to 180°. Surface roughening occurs on the outside of the bending region. Since the strain in the thick zone is greater than that in the thin zone, the surface roughening in the thick zone is more obvious than that in the thin zone. The spring-back angle in the thin zone is higher than that in the thick zone after three-point bending, and the overall spring-back angle of Al-TRB becomes larger with an increasing bending angle. When the transition zone of Al-TRB is centered and the length of the transition zone is certain, as the length of the equal-thickness zone increases, the spring-back angle of the thin zone is larger, while the spring-back angle of the thick zone is smaller. Under the premise of a certain total length of Al-TRB and the length of the transition zone, the larger the length proportion of the thin zone, the larger the overall spring-back angle of Al-TRB, and the larger the length proportion of the thick zone, the smaller the overall spring-back angle of Al-TRB. In addition, a slight metal flow phenomenon exists during three-point bending, which shows that the metal in the bending region will flow to the thick zone, and the metal at the edge will flow to the thin zone. At the same time, there are localized thickening and thinning phenomena in Al-TRB. This study is helpful because it provides theoretical guidance for designing molds for the actual production of Al-TRB parts for automotives.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10856142 | PMC |
http://dx.doi.org/10.3390/ma17030591 | DOI Listing |
J Insect Sci
January 2025
Department of Entomology and Plant Pathology, Auburn University, Auburn, AL, USA.
Aprostocetus hagenowii (Ratzburg) is a generalist parasitoid of cockroach (Blattodea) oothecae. Previous studies examining the host range of A. hagenowii have largely focused on cockroaches of economic and medical importance, which represent a minority of species in an order filled with species of diverse morphology, behavior, and ecology.
View Article and Find Full Text PDFVision (Basel)
January 2025
Department of Ophthalmology, King George's Medical University, Lucknow 226003, India.
Objectives: The goal was to study the ellipsoid zone (EZ) as a structural biomarker for final visual outcomes after pharmacological intervention in center-involving diabetic macular edema (DME) and surgical intervention for full-thickness macular holes (FTMHs).
Methods: This was a tertiary care center-based retrospective study. After sample size calculations, data from 64 consecutive cases were collected, with subjects aged between 40 and 60 years.
Sci Rep
January 2025
Poostchi Ophthalmology Research Center, Department of Ophthalmology, School of Medicine, Shiraz University of Medical Sciences, Shiraz, Iran.
COVID-19 infection has been linked to ocular involvement, particularly retinal microvascular changes. Additionally, prolonged hypoxemia may affect retinal sublayers located within the retinal watershed zone. The aim of this study was to evaluate retinal and optic nerve OCT parameters in patients with COVID-19 illness of varying severity and compare them with controls.
View Article and Find Full Text PDFACS Appl Mater Interfaces
January 2025
Department of Advanced Production Engineering, Engineering and Technology Institute Groningen, Faculty of Science and Engineering, University of Groningen, Nijenborgh 4, Groningen, 9747 AG, The Netherlands.
Ultrashort pulsed (USP) laser burst ablation has attracted numerous interests for its great potential in enhancing ablation efficiency and reducing the heat-affected zone. However, little attention has been paid to the influence of burst ablation on the processed surface quality. To fill this research gap, the present study conducts a comprehensive investigation on the surface processing of stainless steel using ultrashort pulsed laser burst ablation.
View Article and Find Full Text PDFBMC Ophthalmol
January 2025
Department of Refractive Surgery, Guangzhou Aier Eye Hospital, Jinan University, Guangzhou City, Guangdong Province, 510000, China.
Purpose: To evaluate the impact of Implantable Collamer Lens (ICL) implantation on anterior chamber angle parameters and posterior segment structures in highly myopic eyes and explore potential correlations between these changes. The study aimed to assess alterations in superficial and deep vessel density (SVD, DVD), foveal avascular zone (FAZ) area, and retinal nerve fiber layer (RNFL) thickness to clarify the safety profile of ICL implantation.
Methods: Prospective observational study, included 36 highly myopic eyes undergoing ICL implantation in surgery group and 23 non-surgical control eyes in non-surgery group.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!