Purpose: The optimal hinge position to prevent hinge fractures in medial closing wedge distal femoral osteotomy (MCWDFO) based on the biomechanical background has not yet been well examined. This study aimed to examine the appropriate hinge position in MCWDFO using finite element (FE) analysis to prevent hinge fractures.
Methods: Computer-aided design (CAD) models were created using composite replicate femurs. FE models of the MCWDFO with a 5° wedge were created with three different hinge positions: (A) 5 mm proximal to the proximal margin of the lateral epicondylar region, (B) proximal margin level and (C) 5 mm distal to the proximal margin level. The maximum and minimum principal strains in the cortical bone were calculated for each model. To validate the FE analysis, biomechanical tests were performed using composite replicate femurs with the same hinge position models as those in the FE analysis.
Results: In the FE analysis, the maximum principal strains were in the order of Models A > B > C. The highest value of maximum principal strain was observed in the area proximal to the hinge. In the biomechanical test, hinge fractures occurred in the area proximal to the hinge in Models A and B, whereas the gap closed completely without hinge fractures in Model C. Fractures occurred in an area similar to where the highest maximal principal strain was observed in the FE analysis.
Conclusion: Distal to the proximal margin of the lateral epicondylar region is an appropriate hinge position in MCWDFO to prevent hinge fractures.
Level Of Evidence: Level V.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11000132 | PMC |
http://dx.doi.org/10.1002/jeo2.12015 | DOI Listing |
Biol Methods Protoc
February 2025
School of Biological and Chemical Sciences, University of Galway, Galway, H91 TK33, Ireland.
Natural killer (NK) cells have emerged as promising candidates for novel immunotherapy strategies against various malignancies. Their unique ability to recognize and eliminate tumour cells without prior sensitization, coupled with the secretion of pro-inflammatory cytokines such as interferon-gamma and tumour necrosis factor, position them as promising agents in cancer therapy. Adoptive NK cell transfer has shown particular promise in haematological malignancies, where NK cell infusions could achieve remission in a high proportion of patients.
View Article and Find Full Text PDFArthroscopy
March 2025
JMVM Sports Injury Centre, Sitaram Bhartia Institute Of Science & Research, New Delhi.
Predicting anterior cruciate ligament reconstruction (ACLR) failure remains a challenge, shaped by anatomical, biomechanical, surgical, and rehabilitation factors. The lateral femoral notch sign (LFNS), present in 6-52% of ACL injuries, is linked to lateral meniscal tears (40-67%), steeper posterior tibial slope (PTS, 2.7° higher), and cartilage degradation.
View Article and Find Full Text PDFBiomed Phys Eng Express
March 2025
Department of Stomatology, National Cheng Kung University College of Engineering, No.1, University Road, Tainan, 701401, TAIWAN.
This technical note introduces a technique for remounting dental casts to a mechanical articulator using computed tomography (CT) without a facebow. We have developed a jig method that ensures precise remounting by aligning the virtual dental casts to the upper and lower jaw models reconstructed from the CT and transferring them to a virtual articulator based on anatomical landmarks. A custom-designed positioning jig and splint further enhance the accuracy of the process, preserving the spatial relationship between the midface and mandible.
View Article and Find Full Text PDFJ Health Organ Manag
March 2025
Indian Institute of Foreign Trade, New Delhi, India.
Purpose: This paper attempts to elucidate the fundamental determinants-both enablers and impediments-that shape a resilient business ecosystem for the medical devices sector in India, with a particular emphasis on sustainable export endeavours under the ambit of the Medical Devices Policy 2023.
Design/methodology/approach: This study dives into India's medical device export firms, analysing factors influencing their performance. By reviewing relevant literature, it identifies regulatory, manufacturing, marketing, distribution and import-related factors.
IEEE Trans Image Process
March 2025
The goal of pedestrian trajectory retrieval is to infer the multi-camera path of a targeted pedestrian using images or videos from a camera network, which is crucial for passenger flow analytics and individual pedestrian retrieval. Conventional approaches hinge on spatiotemporal modeling, necessitating the gathering of positional information for each camera and trajectory data between every camera pair for the training phase. To mitigate these stringent requirements, our proposed methodology employs solely temporal information for modeling.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!