Background: Gastric emptying (GE), with wide inter-individual but lesser intra-individual variations, is a major determinant of postprandial glycaemia in health and type 2 diabetes (T2D). However, it is uncertain whether GE of a carbohydrate-containing liquid meal is predictive of the glycaemic response to physiological meals, and whether antecedent hyperglycaemia influences GE in T2D. We evaluated the relationships of (i) the glycaemic response to both a glucose drink and mixed meals with GE of a 75 g glucose drink, and (ii) GE of a glucose drink with antecedent glycaemic control, in T2D.

Methods: Fifty-five treatment-naive Chinese adults with newly diagnosed T2D consumed standardised meals at breakfast, lunch and dinner with continuous interstitial glucose monitoring. On the subsequent day, a 75 g glucose drink containing 150 mg C-acetate was ingested to assess GE (breath test) and plasma glucose response. Serum fructosamine and HbA1c were also measured.

Results: Plasma glucose incremental area under the curve (iAUC) within 2 hours after oral glucose was related inversely to the gastric half-emptying time (T50) (r = -0.34, P = 0.012). The iAUCs for interstitial glucose within 2 hours after breakfast (r = -0.34, P = 0.012) and dinner (r = -0.28, P = 0.040) were also related inversely to the T50 of oral glucose. The latter, however, was unrelated to antecedent fasting plasma glucose, 24-hour mean interstitial glucose, serum fructosamine, or HbA1c.

Conclusions: In newly diagnosed, treatment-naive, Chinese with T2D, GE of a 75 g glucose drink predicts the glycaemic response to both a glucose drink and mixed meals, but is not influenced by spontaneous short-, medium- or longer-term elevation in glycaemia.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11001856PMC
http://dx.doi.org/10.1038/s41387-024-00264-8DOI Listing

Publication Analysis

Top Keywords

glucose drink
28
glucose
16
glycaemic response
16
oral glucose
12
mixed meals
12
75 g glucose
12
interstitial glucose
12
plasma glucose
12
gastric emptying
8
predictive glycaemic
8

Similar Publications

Individuals with type 2 diabetes are at high risk of postprandial falls in blood pressure (BP) (i.e., a reduction in systolic BP of ≥20mmHg, termed postprandial hypotension (PPH)), which increases the risk of falls and mortality.

View Article and Find Full Text PDF

Carbohydrate-rich solid foods, such as bread, pasta, and steamed rice, are applied for test meals in studies examining digestion and absorption of food related to glucose metabolism and sports science. Such research must consider that drinking water is sometimes better as it avoids the risk of choking or aspiration. However, the water increases test meal volume and dilutes glucose concentration, which may influence the digestion and absorption of ingested foods, as well as energy metabolism.

View Article and Find Full Text PDF

Background/purpose: Although metabolic dysfunction-associated steatotic liver disease (MASLD) has been proposed to replace the diagnosis of non-alcoholic fatty liver disease (NAFLD) with new diagnostic criteria since 2023, the genetic predisposition of MASLD remains to be explored.

Methods: Participants with data of genome-wide association studies (GWAS) in the Taiwan Biobank database were collected. Patients with missing data, positive for HBsAg, anti-HCV, and alcohol drinking history were excluded.

View Article and Find Full Text PDF

Sensitive fluorescence turn-on sensing of hydroxyl radical and glucose based on the oxidative degradation of reductive organic cage.

Talanta

January 2025

College of Chemistry and Materials Science, Hunan Engineering Research Center for Monitoring and Treatment of Heavy Metals Pollution in the Upper Reaches of Xiangjiang River, Hengyang Normal University, Hengyang, 421001, China. Electronic address:

The accurate and sensitive quantification of hydroxyl radical (·OH) and glucose is necessary for disease diagnosis and health guidance, but still challenging owing to the low concentration of ·OH and poor water solubility of fluorescent probes. In addition, fluorescent probes may cause secondary pollution to the environment. Here an organic cage was reported as a sensitive fluorescent probe for ·OH and glucose in aqueous solution without serious secondary pollution.

View Article and Find Full Text PDF

Heavy alcohol consumption is a known risk factor for type 2 diabetes (T2D), However, the moderating effect of fasting plasma glucose (FPG) levels remains unclear. This study explores the relationship between alcohol intake and T2D risk across FPG strata in a Japanese cohort. Data from 15,453 participants in the NAGALA cohort were analyzed over 5.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!