Download full-text PDF

Source
http://dx.doi.org/10.1111/jce.16276DOI Listing

Publication Analysis

Top Keywords

comparison clinical
4
clinical outcomes
4
outcomes transthoracic
4
transthoracic echocardiography
4
echocardiography x-ray
4
x-ray guided
4
guided left
4
left bundle
4
bundle branch
4
branch pacing
4

Similar Publications

Feasibility of very low iodine dose aortoiliac CT angiography using dual-source photon-counting detector CT.

Eur J Radiol

January 2025

Department of Diagnostic and Interventional Radiology, Medical Center-University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany; Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, USA. Electronic address:

Purpose: To evaluate the feasibility of aortoiliac CT-Angiography (CTA) using dual-source photon-counting detector (PCD)-CT with minimal iodine dose.

Methods: This IRB-approved, single-center prospective study enrolled patients with indications for aortoiliac CTA from December 2022 to March 2023. All scans were performed using a first-generation dual-source PCD-CT.

View Article and Find Full Text PDF

Objective: The potential of robot-assisted (RA) single-position (SP) lateral lumbar interbody fusion (LLIF) warrants further investigation. This study aimed to assess the efficacy of RA-SP-LLIF in improving both clinical and radiographic outcomes in patients undergoing lumbar spinal fusion surgery.

Methods: A total of 59 patients underwent either RA-SP-LLIF (n = 31 cases) or traditional LLIF (n = 28 cases).

View Article and Find Full Text PDF

Motion-Compensated Multishot Pancreatic Diffusion-Weighted Imaging With Deep Learning-Based Denoising.

Invest Radiol

January 2025

From the Department of Radiology, Stanford University, Stanford, CA (K.W., M.J.M., A.M.L., A.B.S., A.J.H., D.B.E., R.L.B.); Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, CA (K.W.); GE HealthCare, Houston, TX (X.W.); GE HealthCare, Boston, MA (A.G.); and GE HealthCare, Menlo Park, CA (P.L.).

Objectives: Pancreatic diffusion-weighted imaging (DWI) has numerous clinical applications, but conventional single-shot methods suffer from off resonance-induced artifacts like distortion and blurring while cardiovascular motion-induced phase inconsistency leads to quantitative errors and signal loss, limiting its utility. Multishot DWI (msDWI) offers reduced image distortion and blurring relative to single-shot methods but increases sensitivity to motion artifacts. Motion-compensated diffusion-encoding gradients (MCGs) reduce motion artifacts and could improve motion robustness of msDWI but come with the cost of extended echo time, further reducing signal.

View Article and Find Full Text PDF

Insomnia and some insomnia treatments can impact an individual's daytime functioning. Here, we performed post hoc analyses of patient-reported outcomes from a phase 3 clinical trial to assess the impact of lemborexant (LEM), a dual orexin receptor antagonist, on daytime functioning. Adults with insomnia were randomized 1:1:1 to receive placebo, LEM 5 mg (LEM5) or LEM 10 mg (LEM10) for 6 months.

View Article and Find Full Text PDF

We aimed to determine whether emergency department (ED) overcrowding affects the occurrence of in-hospital cardiac arrest (IHCA) requiring resuscitation in the ED. This retrospective study was conducted in the ED of a single hospital. We applied the propensity score-matching method to adjust for differences in clinical characteristics in patients who visited the ED during overcrowded conditions.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!