Case History: Medical records from 2009 to 2021 from a private equine referral hospital in Rochester, NH, USA were analysed for cases that underwent general anaesthesia for low-field MRI of the distal limb. These were used to determine peri-anaesthetic morbidity and mortality.

Clinical Findings And Outcome: Two hundred and forty-three anaesthetic episodes were recorded in horses undergoing low-field MRI. The peri-anaesthetic complication rate prior to discharge was 6.2% (15/243). No patients experienced a fatal complication. Ninety two of the 243 patients had multiple sites imaged, 90/243 received pre-anaesthetic dantrolene, 134/243 received intra-anaesthetic dobutamine, and 15/243 were positioned in dorsal recumbency. Complications included: abdominal discomfort ("colic"; 9/243), myopathy (4/243), hyphaema (1/243) and carpal fracture (1/243). At the time of discharge, 14/15 complications had resolved. Of 135 horses for which data were available 55 became hypotensive during the procedure (lowest mean arterial pressure < 65 mmHg). Median body weight was 553 (min 363, max 771) kg. Horses were anaesthetised for a median of 150 (min 45, max 210) minutes. There was no evidence of an association between higher body weight (p = 0.051) or longer duration of anaesthesia (p = 0.421) and development of an anaesthetic complication. For categorical variables (dantrolene administration pre-anaesthesia, dobutamine administration during anaesthesia, hypotension (mean < 65 mmHg) during anaesthesia, dorsal lateral recumbency, and imaging of single multiple sites) the 95% CI for the OR included 1, indicating a lack of effect of the variable on the odds of complication.

Clinical Relevance: The cases included in this series suggest that low-field MRI under general anaesthesia is a viable option for diagnostic imaging in otherwise healthy horses. Complications occur, but most resolve before discharge.

Download full-text PDF

Source
http://dx.doi.org/10.1080/00480169.2024.2321176DOI Listing

Publication Analysis

Top Keywords

low-field mri
12
general anaesthesia
8
multiple sites
8
body weight
8
horses
5
anaesthesia
5
anaesthesia-related morbidity
4
morbidity associated
4
associated recumbent
4
low-field
4

Similar Publications

Monitoring technology for Cr(VI) adsorption and reduction by NMR spectroscopy.

Chem Commun (Camb)

January 2025

Physics Department & Shanghai Key Laboratory of Magnetic Resonance, School of Physics and Electronic Science, East China Normal University, North Zhongshan Road 3663, Shanghai 200062, P. R. China.

This study employs a low-field NMR (LF-NMR) method to investigate Cr(VI) adsorption and reduction in solid-liquid systems, focusing on three cellulose-based amine adsorbents. NMR revealed the effects of molecular structure on adsorption and reduction processes, providing insights into adsorbent design and mass transfer advantages for high-performance Cr(VI) adsorbents.

View Article and Find Full Text PDF

Improving quantification accuracy of a nuclear Overhauser enhancement signal at -1.6 ppm at 4.7 T using a machine learning approach.

Phys Med Biol

January 2025

Vanderbilt University Medical Center, 1161 21st Ave. S, Medical Center North, AAA-3112, Nashville, Tennessee, 37232-2102, UNITED STATES.

Objective: A new nuclear Overhauser enhancement (NOE)-mediated saturation transfer MRI signal at -1.6 ppm, potentially from choline phospholipids and termed NOE(-1.6), has been reported in biological tissues at high magnetic fields.

View Article and Find Full Text PDF

This study introduces a non-destructive, quantitative method using low-field MRI to assess moisture mobility and content distribution in cherry tomatoes. This study developed an advanced 3D non-local mean denoising model to enhance tissue feature analysis and applied an optimized TransUNet model for structural segmentation, obtaining multi-echo data from six tissue types. The structural T2 relaxation inversion was refined by integrating an ACS-CIPSO algorithm.

View Article and Find Full Text PDF

The goal of this study was to determine how radiologists' rating of image quality when using 0.5T Magnetic Resonance Imaging (MRI) compares to Computed Tomography (CT) for visualization of pathology and evaluation of specific anatomic regions within the paranasal sinuses. 42 patients with clinical CT scans opted to have a 0.

View Article and Find Full Text PDF

T* relaxometry of fetal brain structures using low-field (0.55T) MRI.

Magn Reson Med

December 2024

Research Department of Early Life Imaging, School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK.

Purpose: Human brain development during gestation is complex, as both structure and function are rapidly forming. Structural imaging methods using MRI are well developed to explore these changes, but functional imaging tools are lacking. Low-field MRI is a promising modality to bridge this gap.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!