The aim of this study was to evaluate the mechanical behavior of UCLA and Mini-conical abutments for implants with Tri-channel connections regarding torque loss and vertical misfit. Twenty 3-element metal-ceramic fixed partial dentures (FPD) supported by 2 implants were manufactured and divided into 2 groups (n = 10): UCLA (group 1) and Mini-conical Abutments (group 2). The evaluation of torque loss was carried out before and after mechanical cycling, while the vertical fit was evaluated throughout the different stages of manufacturing the prostheses, as well pre- and postcycling (300,000 cycles, 30 N). Statistical analyses of torque loss and vertical misfit were performed using the linear mixed effects model. Both groups showed torque loss after mechanical cycling (P < .05); however, there was no significant percentage differences between them (P = .795). Before cycling, the groups showed a significant difference in terms of vertical misfit values (P < .05); however, this difference was no long observed after cycling (P = .894). Both groups showed torque loss after the cycling test, with no significant difference (P > .05). There was no significant difference in vertical misfit after mechanical cycling; however, in group 1 (UCLA) there was accommodation of the implant-UCLA abutment interface, while group 2 (Mini-conical abutment) did not show changes in the interface with the implant after the test. Both groups behaved similarly regarding the torque loss of the prosthesis retention screws pre- and postmechanical cycling, with greater loss after the test.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1563/aaid-joi-D-23-00033 | DOI Listing |
Dent Res J (Isfahan)
November 2024
Department of Orthodontics and Dentofacial Orthopedics, SRM Dental College and Hospital, Chennai, Tamil Nadu, India.
Background: The aim of this study was to compare the mechanical properties of the polymer brackets with metal and ceramic brackets and verify if the polymer brackets could be used clinically.
Materials And Methods: A thorough search was conducted in four electronic databases, including Scopus, PubMed, Cochrane, Ovid, and Lilacs, with article selection based on Preferred Reporting Items for Systematic Reviews and Meta-Analysis standards. A computerized search of the database was done from January 1990 to June 2024.
Front Neurol
December 2024
Brain Rehabilitation Research Center, Malcom Randall Department of Veterans Affairs Medical Center, North Florida/South Georgia Veterans Health System, Gainesville, FL, United States.
Zhongguo Gu Shang
December 2024
Department of Orthopaedics, Jiangyan Hospital of Traditional Chinese Medicine, Taizhou 225599, Jiangsu, China.
Objective: To explore changes of humerus torque screw tip distance on stability of proximal humeral internal locking system (PHILOS) by finite element analysis, in order to provide reference for selection of intraoperative plant size.
Methods: The proximal humerus 3D model was constructed based on Synbone artificial bone model in 3D engineering drawing software, and the corresponding 3D model was constructed based on PHILOS bone plate contour. The model was modified to simulate comminuted proximal humerus fracture, and the operation model was simulated after fracture, and the fixed operation model was assembled, the apex distance of humerus moment screw was set as 4, 8, 12 and 16 mm respectively.
Anim Nutr
December 2024
State Key Laboratory of Swine and Poultry Breeding Industry, Key Laboratory of Animal Nutrition and Feed Science in South China, Ministry of Agriculture and Rural Affairs, Guangdong Key Laboratory of Animal Breeding and Nutrition, Institute of Animal Science, Guangdong Academy of Agricultural Sciences, Guangzhou 510640, China.
This study was to evaluate the effects of different dietary oils in chicken diets on meat quality, lipid metabolites, the composition of volatile compounds, and gut microbiota. Nine hundred female 817 crossbred broilers at one day old with an average body weight of 43.56 ± 0.
View Article and Find Full Text PDFOral Maxillofac Surg
December 2024
Instituto Militar de Engenharia, Praça General Tibúrcio 80, Urca, Rio de Janeiro, 22290-270, Brazil.
Aim: Insertion of dental implants causes bone deformation and induces residual bone compression stress, which can lead to implant failure if the bone loss threshold is exceeded. The current literature about bone stress is restricted to computer simulations and implant primary stability measurements after installation. This work measures the torque and deformation during implant insertion testing.