Introduction: First-insertion success rates for peripheral vascular access devices (PVADs) in patients with difficult venous access (DIVA) are low, which negatively affects staff workload, patient experience, and organizational cost. There is mixed evidence regarding the impact of a peripheral vascular access device with retractable coiled tip guidewire (GW; AccuCath™, BD) on the first-insertion success rate. The aim of this study is to investigate whether the use of long GW-PVADs, compared with standard PVADs, reduces the risk of first-time insertion failure, in patients admitted to emergency departments (EDs).

Methods And Analysis: A parallel-group, two-arm, randomized controlled trial will be carried out in two Australian EDs to compare long GW-PVADs (5.8 cm length) against standard care PVADs (short or long). Patients ≥18 years of age meeting DIVA criteria will be eligible for the trial. The sample size is 203 participants for each arm. Web-based central randomization will be used to ensure allocation concealment. Neither clinicians nor patients can be blinded to treatment allocation. Primary outcome is the first-insertion success rate. Secondary outcomes include the number of insertion attempts, time to insert PVAD, all-cause failure, dwell-time, patient-reported pain, serious adverse events, complications, subsequent vascular access devices required, patient satisfaction, staff satisfaction, and healthcare costs. Differences between the two groups will be analyzed using Cox proportional hazards regression. Cost-effectiveness analysis will also be conducted. Intention-to-treat analysis will be used.

Ethics And Dissemination: The study is approved by Metro South Ethics Committee (HREC/2022/QMS/82264) and Griffith University (2022/077). The findings will be published in a peer-reviewed journal.

Trial Registration: ACTRN12622000299707.

Download full-text PDF

Source
http://dx.doi.org/10.12968/bjon.2024.33.7.S28DOI Listing

Publication Analysis

Top Keywords

first-insertion success
16
vascular access
12
patients difficult
8
randomized controlled
8
controlled trial
8
peripheral vascular
8
access devices
8
success rate
8
long gw-pvads
8
analysis will
8

Similar Publications

Background: The Laryngeal Mask Airway Vision Mask (LMA VM) is a supraglottic airway device (SAD) with a vision guidance system. The ideal head and neck position for direct laryngoscopy is known, but the ideal position for placing a LMA is not. The objective of this study is to evaluate and compare the optimal position for placement of a video laryngeal mask airway.

View Article and Find Full Text PDF

Background And Aims: Preprocedural ultrasound (PPU) reduces the risk of technical failure in non-obese patients and when technical difficulty is predicted. We conducted this review to determine if PPU improves first-pass needle insertion success for neuraxial anesthesia in patients with obesity.

Methods: We conducted a systematic review without meta-analysis, due to the small number of included studies.

View Article and Find Full Text PDF

Background: A quarter of patients who present to emergency departments (EDs) have difficult intravenous access (DIVA), making it challenging for clinicians to successfully place a peripheral intravenous catheter (PIVC). Some literature suggests that guidewire PIVC improves first-insertion success rate.

Aim: The aim was to determine the clinical and cost-effectiveness of a novel long PIVC (5.

View Article and Find Full Text PDF

Introduction: First-insertion success rates for peripheral vascular access devices (PVADs) in patients with difficult venous access (DIVA) are low, which negatively affects staff workload, patient experience, and organizational cost. There is mixed evidence regarding the impact of a peripheral vascular access device with retractable coiled tip guidewire (GW; AccuCath™, BD) on the first-insertion success rate. The aim of this study is to investigate whether the use of long GW-PVADs, compared with standard PVADs, reduces the risk of first-time insertion failure, in patients admitted to emergency departments (EDs).

View Article and Find Full Text PDF

Background: Supraglottic airway devices (SADs) may be used during laparoscopic procedures in place of the often utilised endotracheal tube. The Proseal laryngeal mask airway (PLMA) is designed with an inflatable cuff, which provides an excellent oropharyngeal seal, and the I-gel is a newer SAD designed with a softer and noninflatable cuff and sharing similar features with PLMA.

Aim And Objectives: This study compared the ease of insertion, haemodynamic and ventilatory parameters as well as morbidities associated with these SADs when used for airway management during diagnostic laparoscopic procedures.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!