In a DFIG grid interconnected system, the control of real and reactive power relies on various factors. This paper presents an approach to regulate the flow of real and reactive power using a Neural Tuning Machine (NTM) based on a recurrent neural network. The focus is on controlling the flow of reactive power from the rotor-side converter, which is proportional to the grid-side controller through a coupling voltage. The proposed NTM method leverages neural networks to fine-tune the parameters of the PI controller, optimizing performance for DFIG grid integration. By integrating dense plexus terminals, also known as dense connections, within the neural network, the control system achieves enhanced adaptability, robustness, and nonlinear dynamics, addressing the challenges of the grid. Grid control actions are based on the voltage profile at different bus locations, thereby regulating voltage. This article meticulously examines the analysis in terms of DFIG configuration and highlights the advantages of the neural tuning machine in controlling inner current loop parameters compared to conventional PI controllers. To demonstrate the robustness of the control algorithm, a MATLAB Simulink model is designed, and validation is conducted with three different benchmarking models. All calculations and results presented in the article strictly adhere to IEEE and IEC standards. This research contributes to advancing control methodologies for DFIG grid integration and lays the groundwork for further exploration of neural tuning methods in power system control.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11344149PMC
http://dx.doi.org/10.1038/s41598-024-56904-7DOI Listing

Publication Analysis

Top Keywords

dfig grid
16
neural tuning
16
grid integration
12
reactive power
12
dense plexus
8
plexus terminals
8
system control
8
real reactive
8
tuning machine
8
neural network
8

Similar Publications

This research is dedicated to improving the control system of wind turbines (WT) to ensure optimal efficiency and rapid responsiveness. To achieve this, the fuzzy logic control (FLC) method is implemented to control the converter in the rotor side (RSC) of a doubly fed induction generator (DFIG) and its performance is compared with an optimized proportional integral (PI) controller. The study demonstrated an enhancement in the performance of the DFIG through the utilization of the proposed FLC, effectively overcoming limitations and deficiencies observed in the conventional controllers, this approach significantly improved the performance of the wind turbine.

View Article and Find Full Text PDF

Transitioning to a power system heavily reliant on renewable wind energy involves more than just replacing conventional fossil-fuel-based power plant with wind farms, the wind energy must be able to meet the requirement of voltage establishment and power balance. It is believed that the self synchronized voltage source control of DFIG wind turbine generator is one of the possible solutions to realize virtual inertia and is helpful to increase the frequency stability of power system, thus is meaningful in the transformation of the power system dominated by renewable energy. Plenty of research has been conducted on the self synchronized voltage source control strategy in steady state, but few research is focused on the soft grid integration, which is a complicated process involving wind turbine control and power converter control.

View Article and Find Full Text PDF

This study presents a novel optimization algorithm known as the Energy Valley Optimizer Approach (EVOA) designed to effectively develop six optimal adaptive fuzzy logic controllers (AFLCs) comprising 30 parameters for a grid-tied doubly fed induction generator (DFIG) utilized in wind power plants (WPP). The primary objective of implementing EVOA-based AFLCs is to maximize power extraction from the DFIG in wind energy applications while simultaneously improving dynamic response and minimizing errors during operation. The performance of the EVOA-based AFLCs is thoroughly investigated and benchmarked against alternative optimization techniques, specifically chaotic billiards optimization (C-BO), genetic algorithms (GA), and marine predator algorithm (MPA)-based optimal proportional-integral (PI) controllers.

View Article and Find Full Text PDF

Low Voltage Ride Through (LVRT) is considered one of the main and serious problems facing the electrical grid. It occurs due to three-phase symmetric faults and asymmetric faults such as a double line to ground fault that applies in this system. This paper applies Static Synchronous Compensators (STATCOM) to improve the LVRT capability and dynamic performance of an electrical grid linked to a Photovoltaic (PV)/Wind hybrid system through grid disturbances.

View Article and Find Full Text PDF

In this paper, a novel control method for Brushless Cascade Doubly-Fed Induction Generator (BCDFIG) control is proposed by integrating the Model Predictive Control (MPC) and the Direct Torque Control (DTC) methods. In previous studies, the DFIG's torque control has been performed, using different methods to improve power production. Here, direct torque control, assisted by model predictive control, is used to maintain output voltage during a change in wind speed and load.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?