While 7T diffusion magnetic resonance imaging (dMRI) has high spatial resolution, its diffusion imaging quality is usually affected by signal loss due to B1 inhomogeneity, T2 decay, susceptibility, and chemical shift. In contrast, 3T dMRI has relative higher diffusion angular resolution, but lower spatial resolution. Combination of 3T and 7T dMRI, thus, may provide more detailed and accurate information about the voxel-wise fiber orientations to better understand the structural brain connectivity. However, this topic has not yet been thoroughly explored until now. In this study, we explored the feasibility of fusing 3T and 7T dMRI data to extract voxel-wise quantitative parameters at higher spatial resolution. After 3T and 7T dMRI data was preprocessed, respectively, 3T dMRI volumes were coregistered into 7T dMRI space. Then, 7T dMRI data was harmonized to the coregistered 3T dMRI B0 (b = 0) images. Last, harmonized 7T dMRI data was fused with 3T dMRI data according to four fusion rules proposed in this study. We employed high-quality 3T and 7T dMRI datasets (N = 24) from the Human Connectome Project to test our algorithms. The diffusion tensors (DTs) and orientation distribution functions (ODFs) estimated from the 3T-7T fused dMRI volumes were statistically analyzed. More voxels containing multiple fiber populations were found from the fused dMRI data than from 7T dMRI data set. Moreover, extra fiber directions were extracted in temporal brain regions from the fused dMRI data at Otsu's thresholds of quantitative anisotropy, but could not be extracted from 7T dMRI dataset. This study provides novel algorithms to fuse intra-subject 3T and 7T dMRI data for extracting more detailed information of voxel-wise quantitative parameters, and a new perspective to build more accurate structural brain networks.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s10548-024-01046-2 | DOI Listing |
Unlabelled: Evaluating tissue microstructure and membrane integrity in the living human brain through diffusion-water exchange imaging is challenging due to requirements for a high signal-to-noise ratio and short diffusion times dictated by relatively fast exchange processes. The goal of this work was to demonstrate the feasibility of imaging of tissue micro-geometries and water exchange within the brain gray matter using the state-of-the-art Connectome 2.0 scanner equipped with an ultra-high-performance gradient system (maximum gradient strength=500 mT/m, maximum slew rate=600 T/m/s).
View Article and Find Full Text PDFMagn Reson Imaging
January 2025
Department of Radiology, Beijing Hospital, National Center of Gerontology, Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, No. 1 Da Hua Road, Dong Dan, Beijing 100730, PR China; Graduate School of Peking Union Medical College, Chinese Academy of Medical Sciences, Beijing, PR China.
Purpose: This study aimed to evaluate the diagnostic efficacy of time-dependent diffusion magnetic resonance imaging (td-dMRI) and dynamic contrast-enhanced MRI (DCE-MRI)-based kinetic heterogeneity in differentiating suspicious breast lesions (categorised as Breast Imaging Reporting and Data System 4 or 5).
Methods: This prospective study included 51 females with suspicious breast lesions who underwent preoperative breast MRI, including DCE-MRI and td-dMRI. Six kinetic parameters, namely peak, persistent, plateau, washout component, predominant curve type, and heterogeneity, were extracted from the DCE series using MATLAB and SPM software.
Front Neurosci
December 2024
Massachusetts General Hospital, Harvard Medical School, Boston, MA, United States.
Objective: High Angular Resolution Diffusion Imaging (HARDI) models have emerged as a valuable tool for investigating microstructure with a higher degree of detail than standard diffusion Magnetic Resonance Imaging (dMRI). In this study, we explored the potential of multiple advanced microstructural diffusion models for investigating preterm birth in order to identify non-invasive markers of altered white matter development.
Approach: Rather than focusing on a single MRI modality, we studied on a compound of HARDI techniques in 46 preterm babies studied on a 3T scanner at term-equivalent age and in 23 control neonates born at term.
Hum Brain Mapp
January 2025
Queen Square Multiple Sclerosis Centre, Department of Neuroinflammation, UCL Queen Square Institute of Neurology, University College London, London, UK.
Disruptions to brain networks, measured using structural (sMRI), diffusion (dMRI), or functional (fMRI) MRI, have been shown in people with multiple sclerosis (PwMS), highlighting the relevance of regions in the core of the connectome but yielding mixed results depending on the studied connectivity domain. Using a multilayer network approach, we integrated these three modalities to portray an enriched representation of the brain's core-periphery organization and explore its alterations in PwMS. In this retrospective cross-sectional study, we selected PwMS and healthy controls with complete multimodal brain MRI acquisitions from 13 European centers within the MAGNIMS network.
View Article and Find Full Text PDFJ Food Prot
December 2024
University of Georgia, Department of Food Science & Technology, 100 Cedar St., Athens, GA 30602, USA.
USDA FSIS recommends meat dwell ≤6 h during cooking from 10 to 54.4°C to limit the growth of Staphylococcus aureus and prevent its production of heat-stable enterotoxins. This study evaluated the growth of S.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!