Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10984695 | PMC |
http://dx.doi.org/10.1503/cmaj.231518 | DOI Listing |
Sci Rep
January 2025
Research and Development, Aesculap AG, Tuttlingen, Germany.
In clinical movement biomechanics, kinematic measurements are collected to characterise the motion of articulating joints and investigate how different factors influence movement patterns. Representative time-series signals are calculated to encapsulate (complex and multidimensional) kinematic datasets succinctly. Exacerbated by numerous difficulties to consistently define joint coordinate frames, the influence of local frame orientation and position on the characteristics of the resultant kinematic signals has been previously proven to be a major limitation.
View Article and Find Full Text PDFUltrasound Med Biol
January 2025
Department of Electrical and Electronic Engineering, The University of Hong Kong, Hong Kong; Biomedical Engineering Programme, The University of Hong Kong, Hong Kong. Electronic address:
Objective: Near-field (NF) clutter filters are critical for unveiling true myocardial structure and dynamics. Randomized singular value decomposition (rSVD) stands out for its proven computational efficiency and robustness. This study investigates the effect of rSVD-based NF clutter filtering on myocardial motion estimation.
View Article and Find Full Text PDFJ Orthop Sci
January 2025
Department of Orthopedic Surgery, Graduate School of Medical Science Kanazawa University, 13-1 Takara-machi, Kanazawa-city, 920-8641, Japan.
Background: Evaluating the correlation between degenerative meniscus tears and medial meniscus extrusion is necessary to determine the appropriate treatment plan for early-stage knee osteoarthritis. This study evaluated the relationship between degenerative meniscal tears and medial meniscus extrusion in early-stage knee osteoarthritis by using ultrasonography.
Methods: A total of 132 knees from 123 patients with early-stage knee osteoarthritis were evaluated retrospectively.
J Thorac Cardiovasc Surg
January 2025
Department of Surgery, Division of Vascular Surgery, University of Maryland School of Medicine.
Objective: We present our experience with endovascular Bentall procedure (Endo-Bentall) using a modular valve conduit (Endo-Bentall) in high-risk patients with aortic root pathologies.
Methods: The physician constructed Endo-Bentall device is composed of a self-expanding transcatheter aortic valve (TAVR), aortic endovascular stent graft (TEVAR), and two wire-reinforced fenestrations for coronary artery stenting. The TAVR valve is sutured into an appropriately sized TEVAR graft.
J Thorac Cardiovasc Surg
January 2025
University of Maryland School of Medicine, Division of Cardiothoracic Surgery. Electronic address:
Objective: Over 30% of patients presenting with acute type A aortic dissection (ATAAD) are considered high - risk or inoperable. This study aims to investigate the early and mid-term outcomes of complex endovascular aortic repair of aortic root, ascending aorta, and aortic arch among patients with ATAAD.
Methods: From January 2018 to January 2023, 29 patients who were considered high risk for open operation underwent endovascular aortic repair.