Background: Femoral neck fractures need to be treated in their early stages with accurate reduction and stable fixation to reduce complications. The authors compared the early radiologic outcomes of femoral neck fractures treated with the recently introduced Femoral Neck System (FNS, Depuy-Synthes) with conventional cannulated screws (CS) in a multicenter design. Furthermore, the factors associated with early failure after FNS were analyzed.

Methods: The FNS group included 40 patients treated between June 2019 and January 2020, and the CS group included 65 patients treated between January 2015 and May 2019. The operation was performed in 3 university hospitals. Patient demographics, fracture classification, postoperative reduction quality, sliding distance of FNS or CS, union and time to union, and complication rates were examined. Logistic regression analysis was performed on candidate factors for early failure of the FNS group.

Results: The FNS group had a 90% union rate and a mean time to union of 4.4 months, while the CS group had similar results with an 83.1% union rate and a mean time to union of 5.1 months. In the subgroup analysis of Pauwels type III fractures, the union rates were 75.0% and 58.8% in the FNS and CS groups, respectively, and the time to union was significantly shorter in the FNS group with 4.8 months compared to 6.8 months in the CS group. Early failure rate within 6 months of FNS fixation was observed to be 10%, which included 3 reduction failures and 1 excessive sliding with a broken implant. Risk factors for early failure after FNS were identified as displaced fractures (Garden classification type III or IV), poor reduction quality, longer tip-apex distance, greater sliding distance, and 1-hole implants, of which sliding distance was the only significant risk factor in multivariate analysis.

Conclusions: In femoral neck fractures, FNS and CS did not show significant differences for short-term radiologic results. FNS resulted in shorter operative time than cannulated screw fixation and favorable outcomes in Pauwels type III femoral neck fractures. The FNS could be considered a reliable and safe alternative to CS when treating femoral neck fractures.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10973613PMC
http://dx.doi.org/10.4055/cios23190DOI Listing

Publication Analysis

Top Keywords

femoral neck
32
neck fractures
24
early failure
16
time union
16
fns
14
failure fns
12
fns group
12
sliding distance
12
type iii
12
femoral
8

Similar Publications

Background:  The aim of the study is to identify the potential risk factors for postoperative AKI in hip fracture patients.

Design And Methods:  Using our local neck of femur (NOF) registration data, patient details were selected using inclusion and exclusion criteria. Electronic records of patients were assessed retrospectively, including blood results, radiological investigations, clinical documentation, and drug charts.

View Article and Find Full Text PDF

Introduction: The occurrence of non-traumatic bilateral femoral neck fractures is exceedingly rare, and their manifestation subsequent to an epileptic attack is an uncommon entity with very few cases reported globally.

Case Report: We present the positive outcome of a 68-year-old man who underwent staged bilateral constrained total hip arthroplasty following a fracture resulting from a generalized seizure. This unconventional decision was justified based on several factors, including fracture pattern, bone quality, seizure history, and advanced tribology.

View Article and Find Full Text PDF

Background: Sequential soft tissue releases are utilized in direct anterior approach (DAA) total hip arthroplasty (THA) as incomplete femoral exposure may lead to complications. This study identifies patient-specific parameters associated with soft tissue releases required for femoral exposure.

Methods: A retrospective review was conducted on 133 patients (150 hips) who underwent primary THA via DAA with a single surgeon.

View Article and Find Full Text PDF

Patients with Type 2 diabetes mellitus(T2DM) typically have an average or higher bone mineral density (BMD) but are at a significantly higher risk of fracture than patients without diabetes. Trabecular bone score (TBS) is a textural index derived from pixel gray-level variations in lumbar spine DXA image, which has been introduced as an indirect measure of bone quality. This study aimed to discuss the trends and annual rates of change in BMD and TBS with age in Chinese men with T2DM and men without diabetes mellitus.

View Article and Find Full Text PDF

Cross-calibration of areal bone mineral densities and body composition between DMS Stratos and Hologic Horizon A dual-energy X-ray absorptiometers: The effect of body mass index.

J Clin Densitom

December 2024

Service de Médecine Nucléaire, Hôpital Lapeyronie, CHU Montpellier, France; Physiologie et Médecine Expérimentale du Cœur et des Muscles (PhyMedEx), INSERM, CNRS, Université de Montpellier (UM), France.

Purpose: The aim of this study was to investigate the correlations between areal bone mineral density (aBMD) and body composition measured by two dual-energy X-ray absorptiometers (DXA), the DMS Stratos® (STR) and the Hologic Horizon A® (HRZ), and then generate cross-calibration equations between the two scanners.

Methods: Repeat scans were obtained from 251 adults (85 % female), 36 ± 14 years old with mean body mass index (BMI) of 28.7 ± 11.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!