A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Accuracy of intraoperative approximation of pelvic tilt using preoperative standing radiographs. | LitMetric

Background: Anterior approach surgeons who utilize intraoperative fluoroscopy often try to match a preoperative radiograph as a reference for intraoperative cup position. Every degree of inaccuracy in tilt leads to a roughly 0.7° change in anteversion. This study aimed to determine how closely pelvic tilt (PT) is approximated intraoperatively when compared to preoperative anteroposterior (AP) radiographs.

Methods: This was a retrospective review of 193 primary THA's done by 2 surgeons at an academic tertiary referral center between September 2021-January 2023. There were 24 patients excluded for distorted anatomy, post-traumatic arthritis, insufficient x-rays, or a sacroiliac joint that could not be visualized on film. Data collected included age and BMI. PT was calculated using the formula, Tilt = -(ln((B/A) x (1/0.483)))/0.051. Value A is the distance from the base of the SI joint to the superior margin of the obturator foramen; value B is the height of the obturator foramen.

Results: Mean preoperative PT was 0.2° versus intraoperative PT was 3.4° (p < 0.001). Mean absolute difference was 6.5°. 48% of patients (n = 81) had an absolute difference less than 5°, 31% (n = 52) between 5° and 10°, 14% (n = 24) between 10° and 15°, and 7% (n = 12) greater than 15°. There was no correlation between BMI or age and PT discrepancy.

Conclusion: Of the patients, 21% had a discrepancy of 10° or greater between their preoperative radiographs and intraoperative fluoroscopic images. Surgeons should be aware of potential errors in cup positioning and be particularly diligent in high-risk cases.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10979016PMC
http://dx.doi.org/10.1016/j.jor.2024.03.026DOI Listing

Publication Analysis

Top Keywords

pelvic tilt
8
accuracy intraoperative
4
intraoperative approximation
4
approximation pelvic
4
preoperative
4
tilt preoperative
4
preoperative standing
4
standing radiographs
4
radiographs background
4
background anterior
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!