Study Objective: Early bleeding is a common source of morbidity associated with left ventricular assist device (LVAD) implantation. Our objective was to identify potential predictors of peri-implant bleeding.
Methods: We conducted a retrospective cohort study of LVAD implants at our institution between January 2010 and November 2018. A total of 210 patients were included. Data were collected for the duration of implant hospitalization, including perioperative invasive hemodynamics, echocardiography and operative details, antiplatelet and anticoagulant use, bleeding events and blood product use, and thromboembolic events. Peri-operative bleeding was defined as a transfusion requirement of >4 units of packed red blood cells in the intraoperative and first 7 days postoperative period, or a major 7-day post-implant overt bleeding event requiring procedural intervention.
Results: Perioperative bleeding occurred in 32% of patients and required surgical re-exploration in 9%. Multivariable logistic regression analysis identified history of previous sternotomy (OR 2.63, 95% CI 1.29 to 5.35, p-value 0.008), preoperative glomerular filtration rate <60 ml/min (OR 2.58, 95% CI 1.34 to 4.94, -value 0.004), preoperative right atrial pressure >13 mm Hg (OR 2.36, 95% CI 1.19 to 4.67, -value 0.014) and concomitant tricuspid valve repair (OR 2.48, 95% CI 1.23 to 5.01, p-value 0.011) as independent predictors of perioperative bleeding. In-hospital thromboembolic events occurred in 5% of patients, but there were no significant predictors for them.
Conclusions: Elevated right atrial pressure appears to be a reversible risk factor for early bleeding that should be targeted during pre-implant optimization of LVAD candidates.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10978136 | PMC |
http://dx.doi.org/10.1016/j.ahjo.2021.100006 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!