Objective: The present review was conducted to test whether the addition of titanium dioxide (TiO) nanoparticles (NPs) within orthodontic bracket adhesives would alter their properties and assess their antimicrobial activity against cariogenic microorganisms in addition to noteworthy mechanical properties.

Materials And Methods: Using predetermined inclusion criteria, an electronic search was conducted using Dissertations and Thesis Global, the Web of Science, Cochrane, Scopus, and Medline/PubMed. Specific terms were utilized while searching the database.

Results: Only seven of the 10 included studies assessed shear bond strength (SBS). The mean SBS among the control group varied from 9.43 ± 3.03 MPa to 34.4 ± 6.7 MPa in the included studies, while in the experimental group, it varied from 6.33 ± 1.51 MPa to 25.05 ± 0.5 MPa. Antibacterial activity was assessed in five of the 10 included studies using TiO NPs, which could easily diffuse through bacterial media to form the growth inhibition zone.

Conclusion: Antibacterial NPs added to orthodontic adhesives at a concentration of 1-5 wt% inhibit bacterial growth and have no effect on bond strength.

How To Cite This Article: D Tivanani MVD, Mulakala V, Keerthi VS. Antibacterial Properties and Shear Bond Strength of Titanium Dioxide Nanoparticles Incorporated into an Orthodontic Adhesive: A Systematic Review. Int J Clin Pediatr Dent 2024;17(1):102-108.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10978508PMC
http://dx.doi.org/10.5005/jp-journals-10005-2729DOI Listing

Publication Analysis

Top Keywords

shear bond
12
bond strength
12
titanium dioxide
12
included studies
12
antibacterial properties
8
properties shear
8
strength titanium
8
dioxide nanoparticles
8
nanoparticles incorporated
8
incorporated orthodontic
8

Similar Publications

Shear bond strength and ARI scores of metal brackets to glazed glass ceramics and zirconia: an in vitro study investigating surface treatment protocols.

BMC Oral Health

December 2024

Faculty of Dentistry, Innovative Dental Materials and Interfaces Research Unit (URB2i), UR 4462, Paris Cité University, 1 rue Maurice Arnoux, Montrouge, 92120, France.

Objective: To evaluate the shear bond strength (SBS) and adhesive remnant index (ARI) scores of metal brackets to glazed lithium disilicate reinforced glass-ceramics and zirconia according to various surface treatment protocols.

Methods: A total of 240 lithium disilicate ceramic (LD) and 240 zirconia (Zr) blocks were randomly divided according to sandblasting, hydrofluoric acid (HF) etching, universal primer use, and the adhesive system applied. A maxillary canine metal bracket was bonded to each sample with resin cement (Transbond XT, TXT).

View Article and Find Full Text PDF

Bond strength between repair and restorative materials is crucial for endodontic success. This study assessed the effects of the following final irrigation solutions on the bond strength of mineral trioxide aggregate (MTA) to a bulk-fill composite: (1) 17% Ethylenediamine tetraacetic acid (EDTA); (2) 2% Chlorhexidine (CHX); (3) 0.2% chitosan; (4) 0.

View Article and Find Full Text PDF

The aim of the study is to assess the impact of mechanical surface treatments on the shear bond strength (SBS) of orthodontic brackets bonded to three-dimensional (3D) printed and milled CAD/CAM provisional materials. Sixty cylindrical samples were fabricated for each provisional material. Samples were treated with one of the following surface treatments: aluminum oxide airborne particle abrasion, diamond bur rotary instrument roughening, and phosphoric acid etching (control).

View Article and Find Full Text PDF

Objectives This study aimed to compare the shear bond strength of three resin cements (light-cured resin cement, pre-heated composite resin, and dual-cured self-adhesive resin cement) when bonding to lithium disilicate discs. Materials and methods Thirty-six discs made of lithium disilicate were fabricated and etched with 9.5% (HF), and 36 human premolars were collected and immersed in the acrylic molds, then randomly divided into three equal groups (n = 12): Group 1: light-cured resin cement, Group 2: pre-heated resin composite, and Group 3: dual-cured resin cement.

View Article and Find Full Text PDF

Evaluation of the shear bond strength of surface-treated Cobalt-Chromium metal crowns on corticobasal® implant abutments cemented using different luting agents.

J Stomatol Oral Maxillofac Surg

December 2024

Reader, Department of Periodontics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai 600077, Tamil Nadu, India.. Electronic address:

Purpose: This in-vitro study aimed to compare the shear bond strength (SBS) of cobalt-chromium (Co-Cr) crowns on Corticobasal® implant abutments, evaluating the effects of two surface treatments and two luting agents.

Materials And Methods: Thirty Co-Cr crowns were fabricated using CAD-CAM technology with a direct metal laser sintering process and divided into three groups based on surface treatment: Group I (untreated), Group II (sandblasted with 50 μm Al₂O₃), and Group III (Er: YAG laser etching). Each group was further subdivided based on luting cement: Sub group A (GC Fuji Plus) and Sub group B (Rely X U200).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!