A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Determining the Optimal Position of Surface Electrodes for Diaphragm Electromyography: A Cross-Sectional Study. | LitMetric

Background: Placing electrodes on different aspects of the chest determines the motor firing from the diaphragm. The electrode placement close to the extent of the muscle gave promising readings as compared to the ones that were placed away. The position with the maximum amplitude and least duration was chosen. Positions of the electrodes were decided as per the extent of the muscle. The aim is to determine the appropriate position of surface electrodes for surface diaphragm electromyography (EMG).

Material And Methodology: Thirty healthy individuals of age ranging from 21 to 45 years were included in the study. Participants were made to lie down in a supine position and different positions like G1 (recording electrode) 5 cm superior to the tip of the xiphoid process and G2 (reference) 16 cm along the costal margin from G1, G1 over the xiphoid tip and G2 at the seventh intercostal space at the costochondral junction and G1 over the xiphoid tip and G2 at the eight intercostal space at the costochondral junction were used for assessing maximum amplitudes and durations were observed by using a Octopus New Wave EMG machine (Octopus Medical Technologies, Vadodara, IND). After observing all the positions, an optimum position for maximum amplitude and least duration was analyzed.

Results: As per the study, out of the four positions, the electrode placements on the tip of the xiphoid process and 16 cm away diagonally on the sixth intercostal space showed maximum amplitude and the least duration with maximum mean amplitude and less mean duration of 232.35 and 7.316. On the seventh intercostal space it was 199.15 and 7.887 and on the eighth intercostal space was 176.055 and 8.639. The tip of the xiphoid process and 16 cm away diagonally on the sixth intercostal space is chosen as the appropriate position for electrode placement for EMG of the diaphragm.

Conclusion: We conclude that the best electrode position was when the electrodes were placed 5 cm superior to the xiphoid process, i.e., G1, and 16 cm away from the recording electrode on the costochondral junction, i.e., G2, at the sixth intercostal space. Ground electrode placement is the nearest bony prominence, i.e., xiphisternum.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10980579PMC
http://dx.doi.org/10.7759/cureus.55176DOI Listing

Publication Analysis

Top Keywords

intercostal space
24
maximum amplitude
16
amplitude duration
16
xiphoid process
16
electrode placement
12
costochondral junction
12
position surface
8
surface electrodes
8
diaphragm electromyography
8
extent muscle
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!