Background: Despite being the gold-standard method for objectively assessing sleep, polysomnography (PSG) faces several limitations as it is expensive, time-consuming, and labor-intensive; requires various equipment and technical expertise; and is impractical for long-term or in-home use. Consumer wrist-worn wearables are able to monitor sleep parameters and thus could be used as an alternative for PSG. Consequently, wearables gained immense popularity over the past few years, but their accuracy has been a major concern.

Objective: A systematic review of the literature was conducted to appraise the performance of 3 recent-generation wearable devices (Fitbit Charge 4, Garmin Vivosmart 4, and WHOOP) in determining sleep parameters and sleep stages.

Methods: Per the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) statement, a comprehensive search was conducted using the PubMed, Web of Science, Google Scholar, Scopus, and Embase databases. Eligible publications were those that (1) involved the validity of sleep data of any marketed model of the candidate wearables and (2) used PSG or an ambulatory electroencephalogram monitor as a reference sleep monitoring device. Exclusion criteria were as follows: (1) incorporated a sleep diary or survey method as a reference, (2) review paper, (3) children as participants, and (4) duplicate publication of the same data and findings.

Results: The search yielded 504 candidate articles. After eliminating duplicates and applying the eligibility criteria, 8 articles were included. WHOOP showed the least disagreement relative to PSG and Sleep Profiler for total sleep time (-1.4 min), light sleep (-9.6 min), and deep sleep (-9.3 min) but showed the largest disagreement for rapid eye movement (REM) sleep (21.0 min). Fitbit Charge 4 and Garmin Vivosmart 4 both showed moderate accuracy in assessing sleep stages and total sleep time compared to PSG. Fitbit Charge 4 showed the least disagreement for REM sleep (4.0 min) relative to PSG. Additionally, Fitbit Charge 4 showed higher sensitivities to deep sleep (75%) and REM sleep (86.5%) compared to Garmin Vivosmart 4 and WHOOP.

Conclusions: The findings of this systematic literature review indicate that the devices with higher relative agreement and sensitivities to multistate sleep (ie, Fitbit Charge 4 and WHOOP) seem appropriate for deriving suitable estimates of sleep parameters. However, analyses regarding the multistate categorization of sleep indicate that all devices can benefit from further improvement in the assessment of specific sleep stages. Although providers are continuously developing new versions and variants of wearables, the scientific research on these wearables remains considerably limited. This scarcity in literature not only reduces our ability to draw definitive conclusions but also highlights the need for more targeted research in this domain. Additionally, future research endeavors should strive for standardized protocols including larger sample sizes to enhance the comparability and power of the results across studies.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11004611PMC
http://dx.doi.org/10.2196/52192DOI Listing

Publication Analysis

Top Keywords

fitbit charge
24
sleep
21
garmin vivosmart
16
charge garmin
12
sleep parameters
12
rem sleep
12
vivosmart whoop
8
systematic review
8
assessing sleep
8
relative psg
8

Similar Publications

Reliability and Accuracy of the Fitbit Charge 4 Photoplethysmography Heart Rate Sensor in Ecological Conditions: Validation Study.

JMIR Mhealth Uhealth

January 2025

ULR 7369 - URePSSS - Unité de Recherche Pluridisciplinaire Sport Santé Société, Univ. Littoral Côte d'Opale, Univ. Lille, Univ. Artois, 189b, Avenue Maurice Schumann, Centre Universitaire des Darses, Dunkerque, 59375, France, 33 328237357.

Background: Wrist-worn photoplethysmography (PPG) sensors allow for continuous heart rate (HR) measurement without the inconveniences of wearing a chest belt. Although green light PPG technology reduces HR measurement motion artifacts, only a limited number of studies have investigated the reliability and accuracy of wearables in non-laboratory-controlled conditions with actual specific and various physical activity movements.

Objective: The purpose of this study was to (1) assess the reliability and accuracy of the PPG-based HR sensor of the Fitbit Charge 4 (FC4) in ecological conditions and (2) quantify the potential variability caused by the nature of activities.

View Article and Find Full Text PDF

Purpose: Effective rehabilitation after orthopaedic surgery is critical. The early post-operative phase is increasingly managed in outpatient settings, necessitating objective measures such as step counts to monitor rehabilitation progress. However, it remains unclear if commercially available wearables or accelerometers using simple algorithms can accurately count steps in early post-operative conditions.

View Article and Find Full Text PDF

Objective: Physical activity (PA) has been linked to reduced Alzheimer's disease (AD) risk. However, less is known about its effects in the AD preclinical stage. We aimed to investigate whether greater PA was associated with lower plasma biomarkers of AD pathology, neural injury, reactive astrocytes, and better cognition in individuals with autosomal-dominant AD due to the presenilin-1 E280A mutation who are virtually guaranteed to develop dementia.

View Article and Find Full Text PDF

Background: Beta-2 agonists play an important role in the management of asthma. Inhaled long-acting beta-2 agonists (LABAs) and short-acting beta-2 agonists (SABAs) cause bronchodilation by stimulating adrenoceptors. These receptors are also present in cardiac cells and, as a side effect, could also be stimulated by inhaled beta-2 agonists.

View Article and Find Full Text PDF

Background: Chemotherapy can cause symptoms that impair quality of life and functioning. Remote monitoring of daily symptoms and activity during outpatient treatment may enable earlier detection and management of emerging toxicities but requires patients, including older and acutely ill patients, to engage with technology to report symptoms through smartphones and to charge and wear mobile devices.

Objective: This study aimed to identify factors associated with participant engagement with collecting 3 data streams (ie, daily patient-reported symptom surveys, passive smartphone sensing, and a wearable Fitbit device [Google]) during chemotherapy.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!