Purpose: To evaluate the safety and effectiveness of various treatment modalities in patients with diabetic retinopathy (DR) who underwent cataract surgery.
Methods: A comprehensive search for randomized controlled trials (RCTs) was conducted using the PubMed, Embase, Cochrane Library, and CNKI databases up to December 22, 2021. The safety and efficacy of treatment modalities were assessed using the risk ratio (RR) to compare the progression of DR and the mean difference to evaluate the best corrected visual acuity (BCVA) and macular thickness (MT).
Results: The meta-analysis of the RCTs revealed that anti-VEGF (anti-vascular endothelial growth factor) drugs significantly reduced the progression of DR [RR: 0.37 (95%CI 0.19, 0.70), P = 0.002] and improved BCVA [mean difference = - 0.06 (- 0.12, - 0.01), P = 0.03] in patients with pre-existing DR who underwent cataract surgery. Steroid drugs also showed a significant reduction in macular thickness [mean difference = - 55.63 (- 90.73, - 20.53), I = 56%, P = 0.002] in DR patients two weeks after cataract surgery compared to the control group. The safety profiles of different management options did not differ significantly.
Conclusion: The present meta-analysis suggests that anti-VEGF drugs can effectively slow down the progression of diabetic retinopathy, improve BCVA, and reduce MT in DR patients who underwent cataract surgery. Steroid drugs also show promise in reducing MT. However, further studies with larger sample sizes are required to compare the efficacy and safety of different management options in a multi-center clinical setting.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s10792-024-02981-6 | DOI Listing |
Clin Ophthalmol
December 2024
Département de Recherche Clinique, Institut Ophtalmologique de l'Ouest (IOO) Jules Verne, Nantes, France.
Purpose: To evaluate clinical outcomes obtained after cataract surgery involving the implantation of a trifocal hydrophobic intraocular lens (IOL) and to determine if pupil size and the corneal aberrometric profile correlate to visual acuity at different distances.
Methods: 49 patients (98 eyes) underwent bilateral cataract surgery with the placement of FineVision HP IOLs for presbyopia and were assessed at 1- and 3- to 6-months post-surgery. Postoperatively, refraction, monocular and binocular uncorrected and corrected distance visual acuity (UDVA and CDVA), uncorrected intermediate visual acuity (UIVA), uncorrected near visual acuity (UNVA) and the binocular defocus curve were measured.
Background: Constituting ~0.5% of all NHS cataract operations, national provision of immediately sequential bilateral cataract surgery (ISBCS) is limited. Combining offering ISBCS within a novel one-stop see-and-treat (S&T) cataract pathway would offer patients the opportunity for two cataract operations in a single hospital visit.
View Article and Find Full Text PDFSci Rep
January 2025
Department of Ophthalmology, Kanazawa Medical University, Kahoku, Ishikawa, Japan.
Photic phenomena are more pronounced in presbyopia-corrected than in monofocal intraocular lens (IOL), causing dissatisfaction after cataract surgery. Photic Phenomena Test (PPT) quantifies photic phenomena in eyes with two types of presbyopia-corrected IOL. We examined the relationship between preoperative eye shape and pupil diameter.
View Article and Find Full Text PDFSci Rep
January 2025
Faculty of Physics, Department of Optics and Optometry and Vision Sciences, Universitat de València, Burjassot, Spain.
A lensless compact arrangement based on digital in-line holography under Gabor's regime is proposed as a novel contactless method to assess the profile of multifocal intraocular lenses (MIOLs) which are conformed by several diffractive rings. Diffractive MIOLs are a widely adopted ophthalmologic option for the correction of presbyopia in patients undergoing cataract surgery. The MIOL optical design might introduce non-negligible optical performance differences between lenses as well as the introduction of undesirable photic phenomena (such as halos and glare) affecting the vision of users.
View Article and Find Full Text PDFCureus
December 2024
Ophthalmology, University of Washington, Seattle, USA.
Objective: This study investigates the refractive accuracy of eight intraocular lens (IOL) power calculation formulas in patients with postoperative refractive surprise after phacoemulsification. It aims to determine if a different formula could result in better refractive outcomes in these eyes.
Methods And Analysis: We retrospectively reviewed consecutive patients undergoing uncomplicated phacoemulsification as a sole procedure between March 2007 and September 2020 at the University of Washington by glaucoma subspecialists as part of a study investigating cataract surgery in normal eyes.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!