AI Article Synopsis

  • Patients with heart failure (HF) and bradycardia may receive different types of cardiac implantable electronic devices (CIED) based on various factors like age and comorbidities, and the study aimed to evaluate their 5-year outcomes post-implantation.
  • The study included 37,745 HF patients in Sweden who received CIEDs from 2005 to 2018 and found significant differences in demographics and outcomes between those receiving implantable cardioverter defibrillators and pacemakers.
  • Results indicated higher mortality rates among single-chamber pacemaker recipients (61%) compared to the average (40%), while cardiovascular mortality was highest in cardiac resynchronization therapy recipients, highlighting how device selection correlates with patient

Article Abstract

Introduction: Patients with heart failure (HF) and bradycardia may be eligible for different types of cardiac implantable electronic devices (CIED), depending on the presence of atrioventricular conduction disease, age, and comorbidities. We aimed to assess the prognosis for these patients, after CIED implantation, stratified for the type of CIED device.

Methods: All patients with preexisting HF diagnosis who received a CIED with a right ventricular lead during the period 2005-2018 in Sweden were identified via the pacemaker registry. Data were crossmatched with the population registry and national disease registries. The outcome was 5-year risk of HF hospitalization and mortality.

Results: A total of 37,745 patients were included in the study. Comparing demographics for implantable cardioverter defibrillator versus pacemaker implants, median age was 66 years versus 83 years, 20% versus 41% were female, 64% versus 50% had ischemic heart disease, and 35% versus 67% had atrial fibrillation (all p < 0.001). Five-year mortality was highest in single-chamber pacemaker recipients (61% compared to average 40%, p < 0.001), but the proportion of cardiovascular mortality was highest for cardiac resynchronization therapy (CRT) recipients (68% vs. 63% p < 0.001). Adjusted mortality was higher for pacemaker patients in all age decile groups (ranging from <60 to >90 years old, all p < 0.001), HF hospitalization occurred in 28% (dual-chamber pacemaker) to 39% (CRT-P) of patients, and cause of death was HF in 15% (dual-chamber pacemaker) to 25% (CRT-D), all p < 0.001.

Conclusion: In this large real-world cohort of CIED-treated patients with prior HF, demography and mortality data indicate that clinicians chose devices according to the overall status of the patient. HF-related events occurred in all groups but were more common in CRT-treated patients.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11449187PMC
http://dx.doi.org/10.1159/000538529DOI Listing

Publication Analysis

Top Keywords

patients
9
patients heart
8
heart failure
8
resynchronization therapy
8
mortality highest
8
dual-chamber pacemaker
8
pacemaker
7
versus
5
age-stratified clinical
4
clinical outcome
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!