A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Cryoablation versus hybrid radiofrequency with high- and very-high-power short-duration catheter ablation for the treatment of paroxysmal atrial fibrillation. | LitMetric

Background: High-power short-duration (HPSD) and very-high-power short-duration (vHPSD-90 W/4 s) radiofrequency (RF) technology has reduced the procedure time of pulmonary vein isolation (PVI) using RF without compromising the efficacy of the technique. The current study compares the novel technology of HPSD/vHPSD with cryoablation (CRYO) in terms of efficacy, safety, and procedure time in a cohort of symptomatic patients with paroxysmal atrial fibrillation (pAF).

Methods: This is a prospective, non-randomized trial. Patients with pAF received either CRYO or HPSD/vHPSD RF PVI. The primary endpoint of the study was arrhythmia recurrence in a 12 month follow-up period. Secondary endpoints included procedure time, fluoroscopy time, and safety.

Results: 104 patients were included (45 in HPSD/vHPSD and 59 in CRYO), with comparable characteristics between groups. The follow-up was 12.4 ± 0.5 months. There was no significant difference regarding arrhythmia recurrences during the early post-procedural period of the first 3 months (8.9% recurrences in HPSD/vHPSD versus 5.1% in CRYO-p 0.463) and in the mid-term follow-up of 12 months (17.8% recurrences in HPSD/vHPSD versus 10.2% in CRYO-p 0.385). Safety was excellent for both procedures. CRYO was a procedure of significantly shorter duration (64.64 ± 8.94 min versus 75.29 ± 18.30 min, p = 0.0001) at the expense of longer fluoroscopy time (HPSD/vHPSD 5.34 ± 1.83 versus 7.89 ± 3.70 min CRYO, p 0.001).

Conclusions: HPSD/vHPSD and CRYO in pAF were comparable regarding the arrhythmia recurrence rates in a 12-month follow-up with excellent safety. The hybrid approach of HPSD/vHPSD has accelerated RF-PVI compared to conventional RF, but CRYO remains a procedure of significantly shorter duration at the expense of longer fluoroscopy time.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.hjc.2024.03.014DOI Listing

Publication Analysis

Top Keywords

procedure time
12
fluoroscopy time
12
very-high-power short-duration
8
paroxysmal atrial
8
atrial fibrillation
8
hpsd/vhpsd
8
arrhythmia recurrence
8
hpsd/vhpsd cryo
8
recurrences hpsd/vhpsd
8
hpsd/vhpsd versus
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!