A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Faster detection of asymptomatic COVID-19 cases among care home staff in England through the combination of SARS-CoV-2 testing technologies. | LitMetric

To detect SARS-CoV-2 amongst asymptomatic care home staff in England, a dual-technology weekly testing regime was introduced on 23 December 2020. A lateral flow device (LFD) and quantitative reverse transcription polymerase chain reaction (qRT-PCR) test were taken on the same day (day 0) and a midweek LFD test was taken three to four days later. We evaluated the effectiveness of using dual-technology to detect SARS-CoV-2 between December 2020 to April 2021. Viral concentrations derived from qRT-PCR were used to determine the probable stage of infection and likely level of infectiousness. Day 0 PCR detected 1,493 cases of COVID-19, of which 53% were in the early stages of infection with little to no risk of transmission. Day 0 LFD detected 83% of cases that were highly likely to be infectious. On average, LFD results were received 46.3 h earlier than PCR, enabling removal of likely infectious staff from the workplace quicker than by weekly PCR alone. Demonstrating the rapidity of LFDs to detect highly infectious cases could be combined with the ability of PCR to detect cases in the very early stages of infection. In practice, asymptomatic care home staff were removed from the workplace earlier, breaking potential chains of transmission.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10980794PMC
http://dx.doi.org/10.1038/s41598-024-57817-1DOI Listing

Publication Analysis

Top Keywords

care staff
12
staff england
8
detect sars-cov-2
8
asymptomatic care
8
december 2020
8
early stages
8
stages infection
8
highly infectious
8
cases
5
faster detection
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!