Objective: The majority of intrauterine devices (IUDs) inserted in China are tailless, requiring intrauterine manipulations for removal and causing pain. This study aimed to investigate the analgesic efficacy of lidocaine injection into a novel disposable injectable cervical dilator for IUD removal procedures.

Study Design: A double-blinded, placebo-controlled, randomized clinical trial was conducted with women aged 18-65 years old requesting outpatient IUD removal. The study randomly assigned participants to either lidocaine (injecting 5 ml of 2% lidocaine into the injectable cervical dilator) or placebo (injecting 5 ml of normal saline into the device) group. All participants received a standardized paracervical block. The primary outcome was pain reported during IUD removal on a 100 mm Visual Analog Scale (VAS). Intention-to-treat were conducted to evaluate the analgesic effectiveness of injecting lidocaine into the injectable cervical dilators.

Results: We enrolled seventy-four eligible participants (37 in lidocaine group and 37 in placebo group). The results showed that the median intraoperative VAS score in the lidocaine group was lower than the placebo group (30.0 mm [IQR 20.0-46.0, n = 37] vs 46.0 mm [IQR 30.0-55.0, n = 37], p = 0.01. In subgroup analyses, among participants with IUD removal and without uterine manipulation and additional procedures, there was no statistically significant disparity observed in intraoperative VAS scores between the lidocaine and placebo group (15.0 mm [IQR 10.0-27.5, n = 8] vs 20.0 mm [IQR 20.0-40.0, n = 6]), p = 0.28). Among participants with an IUD removal necessitating intrauterine manipulations and without additional procedures, showing lower intraoperative VAS scores in lidocaine group (25.0 mm [IQR 15.0-40.5, n = 17]) compared to placebo group (46.0 mm [IQR 38.5-50.0, n = 23]), p < 0.01. Among participants with additional procedures in addition to IUD removal, there was no statistically significant disparity observed in intraoperative VAS scores between the lidocaine and placebo group (41.0 mm [IQR 32.5-57.5, n = 12] vs 45.0 mm [IQR 22.5-69.0, n = 8]), p = 0.97).

Conclusions: Injecting lidocaine into the novel disposable injectable cervical dilator for cervix dilation can significantly reduce pain during an IUD removal, particularly in patients necessitating intrauterine manipulations during IUD removal.

Implications: When we have to perform intrauterine manipulations to remove an IUD, surgical pain and narrow cervical canal undoubtedly affect the implementation of the procedure. Injecting lidocaine into the injectable cervical dilator can achieve local anesthesia while dilating the cervix, and might reduce the choice of general anesthesia for IUD removal.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.contraception.2024.110439DOI Listing

Publication Analysis

Top Keywords

iud removal
20
injectable cervical
16
placebo group
16
cervical dilator
12
lidocaine group
12
intraoperative vas
12
lidocaine
9
efficacy lidocaine
8
novel disposable
8
disposable injectable
8

Similar Publications

Removal of an incarcerated intrauterine device reaching the serosal surface of the uterus by hysteroscopy alone: a case report.

Front Med (Lausanne)

January 2025

Department of Gynecology and Obstetrics, International Peace Maternity and Child Health Hospital Shanghai Jiao Tong University School of Medicine, Shanghai Key Laboratory of Embryo Original Diseases, Shanghai Municipal Key Clinical Specialty, Shanghai, China.

Background: An intrauterine device (IUD) is a widely used long-term contraceptive device for family planning. However, the IUD can lead to various complications. Severe complications and remedial measures caused by IUDs have been reported in the literature; however, detailed surgical approaches for safely removing the IUD within the minimum surgical range have rarely been described especially in postmenopausal women.

View Article and Find Full Text PDF

Background: The use of intrauterine devices (IUDs) for contraception has increased in many countries. However, their application has some serious complications such as uterine perforation and injury to adjacent organs. The translocated IUD into the bladder is a very rare occurrence.

View Article and Find Full Text PDF

Migrated intra-uterine device to infra-umbilical skin: a rare case report.

BMC Womens Health

December 2024

Department of Obstetrics and Gynecology, College of Medicine and Health Sciences, University of Gondar, Gondar, Ethiopia.

Introduction: IUDs are effective, reversible and safe methods of contraception. The mechanism of action of IUDs as a group is inducing endometrial atrophy, apoptosis, altering tubal motility; preventing sperm permeability, fertilization, and implantation. Complications of IUD include menstrual disturbance, pelvic pain, and increased risk of ectopic pregnancy with contraceptive failure, device expulsion, uterine perforation or transmural migration with misplacement of the device.

View Article and Find Full Text PDF

Indwelling intrauterine contraceptive devices (IUDs) have surfaces that facilitate the attachment of spp., creating a suitable environment for biofilm formation. Due to this, vulvovaginal candidiasis (VVC) is frequently linked to IUD usage, necessitating the prompt removal of these devices for effective treatment.

View Article and Find Full Text PDF

The intrauterine device (IUD) is a widely utilized contraceptive method. In cases of uterine rupture, an IUD can migrate to the intra-abdominal or pelvic cavity, leading to various complications such as gastrointestinal perforation. The aim of this study was to report a case of a 29-year-old woman presented with acute left lumber pain.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!