A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Structure solution and refinement of beam-sensitive nano-crystals. | LitMetric

Structure solution and refinement of beam-sensitive nano-crystals.

Micron

Institut Néel, Université Grenoble Alpes, CNRS, Grenoble 38000, France.

Published: June 2024

Radiation sensitive materials are among the most difficult materials to study, even more so if they exist only as nanometer-sized particles, where their size is either intentional because of enhanced properties at the nano-scale or it is unintentional because it is impossible to obtain bigger particles of the same structure. In both cases characterization methods need to be optimized to get the most information out of these particles before the radiation damages them to a point where their structure is altered. When the particles are crystallized, both characteristics, the small size and the beam sensitivity, call for electron diffraction as a privileged investigation tool. The strong interaction of electrons (as compared to X-rays) with matter allows single crystal diffraction experiments on nanometer-sized crystals and for the same amount of beam damage, electron diffraction yields more information than X-rays. These inherent advantages of electron diffraction are optimized in the recently developed low-dose electron diffraction tomography (LD-EDT) by minimizing the necessary dose for a complete data collection. In this contribution we show that in some cases even doses as low as 2 e/Ų can induce damage in crystal structures that inhibit a correct structure refinement. However, by LD-EDT we can obtain data using extremely low doses that don't alter the structure which make it then possible not only to solve crystal structures but also to refine them using dynamical diffraction theory. Here a synthetic oxide containing volatile Na and a metal-organic framework are given as examples. A dynamical refinement of the structures is possible with data sets requiring a dose of less than 0.15 e/Ų.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.micron.2024.103634DOI Listing

Publication Analysis

Top Keywords

electron diffraction
16
crystal structures
8
diffraction
6
structure
5
structure solution
4
solution refinement
4
refinement beam-sensitive
4
beam-sensitive nano-crystals
4
nano-crystals radiation
4
radiation sensitive
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!